This property is used to set the source is used as the position capture. This property takes the values 0 - for the motor position capture or 1 – for  the external position capture .

Short form

<axis>.CapSrc

Syntax

<axis>.CaptureSource = <value>

Availability

All versions

Type

Long

Range

0 – motor

1 - external source

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • Can be set in SERCOS communications phase 2.
  • Read only in communications phase 4
  • Not supported in EtherCAT system

Examples

ser.phase=0

a1.CaptureSource = 1                     ' Capture external position