softMC通常通过串口向主机传送错误代码。
一些错误代码也会传输到状态显示器。
EEPROM中的错误历史记录(FLTHIST,ERR)中保存了相同的信息,因此断电时不会丢失任何信息。
不是所有的错误都反映了一个消息回到主机。 在这种情况下,没有消息的错误只传达到状态显示。
Number |
Message |
Description |
Type |
Severity |
Action |
1 |
CPU Divide error |
如果除数为零或商数溢出结果寄存器,则由CPU产生。 |
ASYNC |
致命错误 |
Watchdog |
2 |
CPU Debug |
如果设置了Trap标记,则在每条指令之后由CPU产生。 |
ASYNC |
致命错误 |
Watchdog |
3 |
CPU NMI |
当输入到NMI引脚时,由CPU产生 |
ASYNC |
致命错误 |
Watchdog |
4 |
CPU Breakpoint |
由一个字节的断点指令生成。 |
ASYNC |
致命错误 |
Watchdog |
5 |
CPU Detected Overflow |
如果设置了溢出标志, 则由 CPU 生成。 |
ASYNC |
致命错误 |
Watchdog |
6 |
CPU Bound range exceed |
当要测试的值小于指定的下限或大于指定的上限时,由BOUND指令生成。 |
ASYNC |
致命错误 |
Watchdog |
7 |
Invalid opcode |
当CPU尝试执行无效操作时生成。 |
ASYNC |
致命错误 |
Watchdog |
8 |
CPU extension not available |
如果遇到协处理器指令,并且未安装协处理器,则生成该错误。 |
ASYNC |
致命错误 |
Watchdog |
9 |
CPU: double exception detected |
在一个CPU指令或异常处理程序中发生多个异常时生成。 |
ASYNC |
致命错误 |
Watchdog |
10 |
CPU Coprocessor overrun |
如果协处理器试图访问片段边界之外的内存,则生成错误。 |
ASYNC |
致命错误 |
Watchdog |
11 |
CPU Invalid Task State Segment |
如果任务门指定的新TSS无效,则在任务切换期间由CPU自动生成。 |
ASYNC |
致命错误 |
Watchdog |
12 |
CPU segment not present |
如果段描述符指示段当前不在内存中,则在加载CPU的段寄存器时生成。 |
ASYNC |
致命错误 |
Watchdog |
13 |
CPU Stack fault |
在堆栈溢出,下溢或层间转换或任务切换引用标记为"不存在"的堆栈段时生成。 |
ASYNC |
致命错误 |
Watchdog |
14 |
CPU General protection fault |
当CPU检测到不适用于具有单独中断的另一类别的保护违规时生成。在80486保护模式浮点保护错误上产生此错误。 |
ASYNC |
致命错误 |
Watchdog |
15 |
CPU Page fault |
在尝试访问一个 4 K 内存页, 该页面的页表项已清除 "当前" 位时生成该错误。 |
ASYNC |
致命错误 |
Watchdog |
16 |
CPU Coprocessor fault |
如果处理器试图访问段边界外的内存, 则生成该错误。它可能在协处理器指令发出后的任意时间发生。 |
ASYNC |
致命错误 |
Watchdog |
17 |
CPU Alignment error |
如果内存未对齐,则由CPU自动生成错误。 |
ASYNC |
致命错误 |
Watchdog |
18 |
Invalid FPU operation |
程序错误(例如,三角函数的超范围参数,负操作数的SQRT,零或负操作数的对数)。 |
ASYNC |
错误 |
Idle Task |
19 |
FPU: Unnormalized operand |
当一条指令试图对一个未规范化的操作数进行操作时产生。 由于丢失了低位,结果可能会显着性降低。 |
ASYNC |
错误 |
Idle task |
20 |
FPU divide by zero |
当指令尝试除以零时生成该错误。 |
ASYNC |
错误 |
Idle Task |
21 |
FPU overflow |
如果四舍五入结果的大小超过目标格式中最大有限数的大小,则发生该错误。 |
ASYNC |
错误 |
Idle Task |
22 |
FPU Underflow |
两个相关的事件可能导致这个错误: 1) 创建一个非常小的操作数,以后可能会导致一些其他异常,2) 在除法时溢出产生不精确的结果。 |
ASYNC |
错误 |
Idle Task |
23 |
FPU Precision lost |
在操作结果不能完全以目标格式表示时发生。 例如,1/3不能以二进制形式精确表示。 这种异常频繁发生,表明有一些(通常可接受的)异常已经丢失。 大多数应用程序掩盖此异常 |
ASYNC |
错误 |
Idle task |
24 |
FPU Stack fault |
由于堆栈溢出或下溢,在FPU上生成错误。 |
ASYNC |
错误 |
Idle Task |
25 |
Invalid FPU operation |
程序错误(例如,三角函数的超范围参数,负操作数的SQRT,零或负操作数的对数)。 系统上下文 |
ASYNC |
致命错误 |
Watchdog |
26 |
FPU: Unnormalized operand |
当一个指令试图操作一个非标准化的操作数时,由于丢失了低位,结果可能会显着性降低。 大多数应用程序都会屏蔽这个异常,因为非标准化的操作数在加载到FPU时将被标准化为扩展实数格式。 系统上下文 |
ASYNC |
致命错误 |
Watchdog |
27 |
FPU Zero divide |
当指令试图将有限的非零操作数除以零时生成。 系统上下文。 |
ASYNC |
致命错误 |
Watchdog |
28 |
FPU Overflow |
如果四舍五入结果的大小超过目标格式中最大有限数的大小,则发生该错误。 |
ASYNC |
致命错误 |
Watchdog |
29 |
FPU Underflow |
两个相关的事件导致了这个错误:1)创建一个非常小的操作数,以后可能会导致一些其他的异常,2)除以时溢出产生不精确的结果。 |
ASYNC |
致命错误 |
Watchdog |
30 |
FPU Precision lost |
在操作结果不能完全以目标格式表示时发生。 例如,1/3不能以二进制形式精确表示。 这种异常频繁发生,表明有一些(通常可接受的)异常已经丢失。 大多数应用程序掩盖此异常 |
ASYNC |
致命错误 |
Watchdog |
31 |
FPU Stack fault |
由于堆栈溢出或下溢,在FPU上生成错误。 |
ASYNC |
致命错误 |
Watchdog |
32 |
Unknown module ID |
内部错误。 错误代码中遇到的未注册的模块代码。 |
ASYNC |
致命错误 |
Watchdog |
33 |
Failed to create Logger message queue |
内部系统资源不能分配 |
ROOT |
致命错误 |
Watchdog |
34 |
Failed to create logger task |
内部错误。 联系技术支持。 |
ROOT |
致命错误 |
Watchdog |
35 |
Failed to write logger file |
写入日志文件时发生错误。 如果同时产生很多错误,就会发生这种情况。 |
ASYNC |
错误 |
None |
36 |
Invalid logger message queue ID |
内部错误。联系技术支持。 |
ASYNC |
致命错误 |
Watchdog |
37 |
Failed to create logger mutex |
内部错误。联系技术支持。 |
ROOT |
致命错误 |
Watchdog |
38 |
Invalid logger mutex |
内部错误。联系技术支持。 |
ASYNC |
致命错误 |
Watchdog |
39 |
Task does not exist |
在任务不存在时响应ERROR或ERRORNUM任务查询而生成错误。 |
SYNC |
Note |
None |
40 |
Invalid message queue |
无效的消息队列ID |
SYNC/ ASYNC |
致命错误 |
Watchdog |
41 |
Failed to create Error Handler task |
内部错误。联系技术支持。 |
ROOT |
致命错误 |
Watchdog |
42 |
Failed to create Error Handler message queue |
内部错误。联系技术支持。 |
ROOT |
致命错误 |
Watchdog |
43 |
Error message queue overflow |
错误太多。 有些错误信息可能会丢失。 |
ASYNC |
错误 |
None |
44 |
Logger message queue overflow |
错误消息流量太多。 有些错误信息可能会丢失。 |
ASYNC |
错误 |
None |
46 |
Could not stop Interpreter |
用户进程不能被默认的系统错误处理程序停止。 |
ASYNC |
致命错误 |
Watchdog |
47 |
Cannot proceed user error handler |
内部错误。联系技术支持。 |
ASYNC |
致命错误 |
Watchdog |
48 |
Error code with invalid severity |
内部错误。联系技术支持。 |
ASYNC |
致命错误 |
Watchdog |
49 |
Error code with invalid context info |
内部错误。联系技术支持。错误处理程序状态机识别的上下文值无效。 |
ASYNC |
致命错误 |
Watchdog |
50 |
Cannot open logger file |
打开记录器文件时发生文件系统错误。 |
ASYNC |
错误 |
None |
51 |
User error handler cannot be created. |
产生用户错误处理程序任务时发生错误。增加内存。 |
SYNC |
错误 |
None |
52 |
User error handler message queue failed |
内部错误。联系技术支持。 |
SYNC |
致命错误 |
Watchdog |
53 |
User error handler stack allocation failed. |
无法创建内部数据结构。增加内存或卸载不必要的任务。 |
SYNC |
错误 |
None |
54 |
Recurring attempt to define user system error handler |
用户系统错误处理程序只有一个实例可能存在。 |
SYNC |
错误 |
Idle Task |
55 |
Unsuccessful OnSystemError kill |
用户错误处理程序无法运行。 |
ASYNC |
错误 |
Idle Task |
56 |
Bad exception handle |
异常句柄错误 |
SYNC |
错误 |
Idle Task |
57 |
Bad exception number |
错误的异常号 |
SYNC |
错误 |
Idle Task |
58 |
Exception number is already used |
已使用异常号 |
SYNC |
错误 |
Idle Task |
59 |
No memory |
内存不足 |
SYNC |
错误 |
Idle Task |
60 |
Too many user defined exceptions |
用户定义的例外太多 |
SYNC |
错误 |
Idle Task |
61 |
Invalid error print level |
无效的错误打印级别 |
SYNC |
错误 |
Idle Task |
62 |
Unknown error |
错误代码不能被错误处理程序识别。 |
ASYNC |
致命错误 |
Watchdog |
63 |
On System Error queue is full |
系统错误队列已满 |
SYNC |
错误 |
Idle Task |
64 |
Fault.log file was invalid see Fault.bak file |
Fault.log文件无效,请参阅Fault.bak文件 |
SYNC |
错误 |
Idle Task |
65 |
Error occurred in the attached motion element. |
如果系统中出现任何未注册的错误,则关联运动元素的所有任务都会因此错误而停止。 |
ASYNC |
错误 |
Idle Task |
66 |
CPU overload. |
用户任务进入繁忙循环超过4秒钟。增加延迟 |
ASYNC |
错误 |
Idle Task |
Number |
Message |
Description |
Type |
Severity |
Action |
3001 |
Maximum number of groups in the system exceeded |
系统中定义的组超过允许的组。系统最多支持32个组。当输入的元素多于允许的元素时,SYNCSTART命令也会发生错误。 |
SYNC |
错误 |
|
3002 |
Non-existent axis |
内部错误。 给出一个未知的轴号。 这个错误只能通过解释器的无效输入引起。 |
SYNC |
致命错误 |
Watchdog |
3003 |
Non-existent group |
内部错误。 给出了一个未知的组号。 输入了无效的组句柄。 此错误只能通过解释器中的无效组地址引起。 |
SYNC |
致命错误 |
Watchdog |
3004 |
Too many axes in group |
组中定义的轴数太多。组中轴的数量限制为32。 |
SYNC |
错误 |
|
3005 |
Non-existent group or axis |
内部错误。输入了无效的组或轴的句柄。句柄用于组和轴。如果不清楚轴或组是否被访问,并且句柄指向不存在的元素,则返回错误。 |
SYNC |
致命错误 |
Watchdog |
3006 |
Element is already attached to a task |
元素已经关联到一个任务。 在ATTACH命令或任何需要关联权限的命令中出现错误。 |
SYNC |
错误 |
Idle Task |
3007 |
Invalid mode |
内部错误。给定的模式无效。根据发出的命令(MOT_MODAL,MOT_NODAL,MOT_IMMEDIATE),模式只能有一定的数值。 |
SYNC |
致命错误 |
Watchdog |
3008 |
Velocity out of range |
速度的值不在该系统变量(最大速度,巡航速度,最终速度...)的允许范围内。 例如,A1.VMAX=-1。 |
SYNC |
错误 |
Idle Task |
3009 |
Time value out of range |
无效的持续时间值给出。 时间值(通常是时间间隔)不在允许的范围内。 |
SYNC |
错误 |
Idle Task |
3010 |
Wrong parameter value. |
提供的命令值无效。 在所有运动命令中检查命令参数的适当值(STOPTYPE,PROCEEDTYPE,...) |
SYNC |
错误 |
|
3011 |
Not available nodal package. |
内部错误。该变量目前不可用。可以查询节点变量,但用户命令集不支持该功能。节点包并不总是可用的。 |
SYNC |
致命错误 |
Watchdog |
3012 |
Acceleration out of range |
加速度的值不在允许的加速度值的范围内。 例如,A1.ACC=-1 |
SYNC |
错误 |
|
3013 |
Deceleration out of range |
减速度的值不在允许的减速度值的范围内。 例如,A1.DEC=-1 |
SYNC |
错误 |
|
3014 |
Jerk out of range |
加加速度值不在允许的加加速度值的范围内。例如A1.JERK=-1 |
SYNC |
错误 |
|
3015 |
Velocity override out of range |
速度覆盖的值超出了允许值的范围。例如 A1.VELOCITYOVERRIDE=-1 |
SYNC |
错误 |
|
3016 |
Group envelope error |
该组的位置误差大于PEMAX指定的允许误差。 |
ASYNC |
错误 |
运动停止 |
3017 |
Axis following error: |
轴的位置误差大于由PEMAX指定的允许误差。 |
ASYNC |
错误 |
运动停止 |
3018 |
Wrong position value. |
给出的位置值无效。给定的位置超出了该轴定义的位置范围。 |
SYNC |
错误 |
|
3019 |
Axis belongs to a group. |
内部错误。无法删除属于组的轴。 |
SYNC |
致命错误 |
Watch dog |
3020 |
The element is moving |
尝试从监视器输入三个MOVE命令时会返回此错误。从监视器只能有两个MOVE命令缓存。当轴已经运动时尝试启用齿轮传动或凸轮运动时,也会返回错误。 |
SYNC |
错误 |
|
3021 |
At axis. Input switch might have been dedicated to an other function |
当输入切换模式功能改变时,返回该注释 |
SYNC |
Note |
None |
3022 |
Homing maximum distance exceeded - aborting homing procedure |
在回原点时,超过最大回原点行程极限 |
SYNC |
错误 |
|
3023 |
The action is not allowed in this CONMODE |
N/A for MC |
N/A |
N/A |
|
3024 |
Unknown mechanical model |
无效的模型类型。 模型类型用于指定机械结构。 |
SYNC |
错误 |
|
3025 |
Axis active in a group. |
组的轴不能独立于组关联或分离。 |
SYNC |
错误 |
|
3026 |
Motion inhibited: Set Motion flag to ON |
运动指定的元素被MOTION属性禁止。 |
SYNC |
错误 |
|
3027 |
Circle can be done in 2 or 3D |
CIRCLE命令不能在少于2个轴或3个轴的组上执行。 |
SYNC |
错误 |
|
3028 |
Not available at this state |
N/A for MC |
SYNC |
错误 |
|
3029 |
The group cannot be synchronized with its axes. |
组和它的轴不能同步。 |
SYNC |
错误 |
|
3030 |
Attachment Error : Different motion types |
只有当它们的轴具有相同的运动类型时,才能关联或运动该组。 轴运动类型可以是LINEAR或ROTARY。 |
SYNC |
错误 |
|
3031 |
This command is not allowed during AI |
某些命令(如CIRCLE,DELAY,WAITFORMOTION,...)在高级插补过程中不能使用。 |
SYNC |
错误 |
|
3032 |
Axis specified more than once in group |
该组不能由一个轴的多个实例组成。 |
SYNC |
错误 |
|
3033 |
SYNC flag not set. Set STARTTYPE to SYNC |
SYNCSTART命令是在StartType没有被定义为SYNC的元素上运行的。 |
SYNC |
错误 |
|
3035 |
Synchronized movement is pending. Clear sync using SYNCCLEAR command |
运动元素存在一个挂起的同步运动。 在发出SYNCSTART命令之前,运动元素无法运动,或者使用SYNCCLEAR清除同步。 |
SYNC |
错误 |
|
3036 |
Automatic braking |
元素正在自动停止。当最终速度不为零并且没有挂起的运动命令时,可能会发生这种情况。 |
ASYNC |
错误 |
|
3037 |
Not stopped. |
给一个没有停止的元素的proceed命令。 |
SYNC |
错误 |
|
3038 |
The element is stopped from another task |
元素被其他任务停止时,无法定义齿轮或凸轮。在这种情况下,STOP命令也禁止运动。 |
SYNC |
错误 |
|
3039 |
Only the task can Proceed |
该元素已被任务停止。PROCEED命令必须从任务发出,而不是从终端发出。 |
SYNC |
错误 |
|
3040 |
Only the monitor can Proceed |
已经由终端的STOP命令停止的运动元素只能由终端的PROCEED命令启动,而不能从另一个任务启动。 |
SYNC |
错误 |
|
3041 |
Nothing to proceed |
PROCEED命令在一个尚未停止的元素上发出。 |
SYNC |
Note |
|
3042 |
Proceed in progress. |
对于PROCEED和STOP命令有一些限制。详情请参阅参考手册。 |
SYNC |
错误 |
|
3043 |
Cannot execute move. Element is stopped by another task. |
当一个元素用STOP命令停止后,不能执行,直到执行STOP命令的同一个任务发出一个PROCEED命令。 |
SYNC |
错误 |
|
3044 |
Jog is not allowed on group: specify axis name |
点动只能在一个轴上完成。 |
SYNC |
错误 |
|
3045 |
Wrong speed override value. |
设置VELOCITYOVERRIDE功能的百分比是有限的。 请参阅参考手册了解允许的范围。 |
SYNC |
错误 |
|
3046 |
Smooth factor out of range |
给定的平滑值不在范围内。请参阅参考手册了解允许的范围。 |
SYNC |
错误 |
|
3047 |
Excessive Jerk/Acceleration ratio: decrease jerk or increase accel and decel |
加速度比率定义了达到最大加速度所需的时间。此时间不能少于5个运动采样周期。该比例受限于0.9 * PI /(5T),其中T是以毫秒为单位的周期时间。因此,当循环时间是2毫秒时限制是282.74,当循环时间是4毫秒时是141.37。使用从0到100的SMOOTHFACTOR来解决JERK的限制。 |
SYNC |
错误 |
|
3048 |
Proceed command may be entered from monitor |
如果停止运动的任务在没有提供PROCEED命令的情况下被终止或终止,则允许从终端接收PROCEED命令。 |
SYNC |
Note |
|
3049 |
Group is stopped: at least one of its axes is disabled or in following mode |
由于其中的一个(或多个)轴已禁用或进入跟随模式,组停止。 |
SYNC |
Note |
|
3050 |
The movement has been recalculated |
运动状态有变化,在运动计算开始之前,但在此之前,运动可以执行。 |
SYNC |
Note |
|
3051 |
The current operation mode doesn't allow this action |
N/A for MC |
SYNC |
错误 |
|
3052 |
Circle plane out of range: must be 0, 1 or 2 |
CIRCLE命令可以在XY平面,YZ平面或XZ平面中执行。在CIRCLE命令中,这些平面分别使用值0,1和2指定。 |
SYNC |
错误 |
|
3053 |
Wrong master declaration. |
主类型的定义错误。 检查主源分配的递归。 |
SYNC |
错误 |
|
3054 |
Invalid slave specification |
尝试将组指定为从轴时发生此错误,例如G1.MasterSource = A1.PCMD。一个组不能被声明为从属。当主/从规格超出范围时也会发生。 例如,A1.SLAVE = 3 |
SYNC |
错误 |
|
3055 |
The element is already a slave |
当轴已经是从轴时,不能声明主轴或从轴类型(齿轮或凸轮)。 |
SYNC |
错误 |
|
3056 |
One of the axes in the group is a slave: absolute motion not allowed |
如果组中的某一个轴被设置为从轴,则不允许在组上进行绝对位置运动。 |
SYNC |
错误 |
|
3057 |
Absolute move not allowed on slave axis |
在尝试在从动轴上执行绝对运动命令时发生。 从轴上只允许增量移动。 |
SYNC |
错误 |
|
3058 |
The drive is disabled or in the following mode; no motion allowed |
如果驱动器被禁用或轴处于跟随模式,则无法执行运动命令。 |
SYNC |
错误 |
|
3059 |
Master axis unknown: specify master source |
主轴声明丢失时产生该错误。当一个轴被声明为一个从轴时,会检查主轴是否存在。 |
SYNC |
错误 |
|
3060 |
Invalid cam index |
内部错误。出现凸轮查询并且不能识别凸轮时,会显示此错误。 |
SYNC |
致命错误 |
|
3061 |
Can't declare more cam tables. |
凸轮表格不能被定义。 只能定义256个凸轮表。 |
SYNC |
错误 |
|
3062 |
Wrong cam table size |
凸轮表尺寸必须为16模。使用LOADCAMDATA命令加载凸轮文件时会返回此错误。 |
SYNC |
错误 |
|
3063 |
Problem reading cam data file: verify file size and existence. |
从文件读取数据时出现问题。 从文件中读取的数据项的数量与文件大小不匹配,或者文件不存在。 |
SYNC |
错误 |
|
3064 |
No NEXT cam table: camming terminated and slave axis stopped |
凸轮表的末端已经到达,没有下一个凸轮表。轴停止并退出从轴模式。 |
ASYNC |
Note |
|
3065 |
No PREVIOUS cam table: camming terminated and slave axis stopped |
已经到达凸轮表的起始点,没有之前的凸轮表。轴停止并退出从轴模式。 |
ASYNC |
Note |
|
3066 |
Two identical master values inside cam table: change cam table |
当检查单调性时,在凸轮表内找到两个相同的主值。 |
SYNC |
错误 |
|
3067 |
The cam table is not monotonic |
凸轮表必须是单调的(向上或向下)。当一个轴被声明为一个从轴或者当一个文件被加载到一个凸轮表中时,检查单调性。 |
SYNC |
错误 |
|
3068 |
Cam offset not found in the cam table |
在凸轮表中找不到指定的CAMOFFSET。 必须将CAMOFFSET的值作为凸轮表中的主位置值之一。 |
SYNC |
错误 |
|
3069 |
The cam table is already linked: unlink table before changing it |
链接后,文件无法加载到凸轮表中。 如果已链接,凸轮表不能被删除。 |
SYNC |
错误 |
|
3070 |
Not calibrated. |
内部错误 |
SYNC |
错误 |
|
3071 |
Already calibrated/configured |
N/A for MC |
N/A |
N/A |
|
3072 |
Enabled. |
如果元素已使能,则不能发出configgroup命令,而在使能驱动器时,不能执行其他的操作。 |
SYNC |
错误 |
|
3073 |
Time cannot be negative. |
TIME必须为正值. |
SYNC |
错误 |
|
3074 |
Cam table is empty. |
加载文件时或轴被声明为从轴(凸轮模式)时检查凸轮表 |
SYNC |
错误 |
|
3075 |
Gear ratio out of range |
电子齿轮比超出范围。 参考参考手册中的GEARRATIO轴属性。 |
SYNC |
错误 |
|
3076 |
Value could not be queried in a single cycle time. |
查询实时矢量变量时,需要从一个采样周期中获取所有的坐标值。 如果系统过载,这是不可能的。 |
SYNC |
错误 |
|
3077 |
The Cam data array is in use |
当使用凸轮数据数组时,其操作受到限制: 1) 将文件加载到数据数组中, 2) 保存数组, 3) 重新创建数据数组 , 4) 将从轴或主轴值写入数组。当该数组是该轴的活动凸轮时,正在使用凸轮数据数组。 |
SYNC |
错误 |
|
3078 |
Cam cycles out of range |
指定的凸轮循环数超出范围。 请参阅参考手册中的CYCLE凸轮属性说明。 |
SYNC |
错误 |
|
3079 |
No active cam. |
没有为轴定义凸轮。在执行以下轴属性:ACTIVECAM,CAMCYCLE,CAMINDEX查询时,将返回此错误。 |
SYNC |
错误 |
|
3080 |
Wrong file extension: must be .cam |
凸轮文件的扩展名必须是.CAM |
SYNC |
错误 |
|
3081 |
Cam chain is not connected correctly. |
当轴移动到下一个或上一个表格时,将检查表格之间的连接。 如果连接不正确,则轴停止并退出从轴模式 |
ASYNC |
错误 |
|
3082 |
Feedback velocity is out of limit |
实际速度受VELOCITYOVERSPEED属性的限制。 当实际速度超过VELOCITYOVERSPEED时,运动停止。 |
ASYNC |
错误 |
运动停止 |
3083 |
Feedback velocity is out of limit when motion is stopped: drive disabled |
实际速度受VELOCITYOVERSPEED属性的限制。 当实际速度超过VELOCITYOVERSPEED时,运动停止。 如果在运动已经停止时发生这种情况,则驱动器被禁用。 这可能表示驱动器调试问题或噪音问题。 |
ASYNC |
错误 |
驱动器被禁用 |
3084 |
Wrong velocity over speed value |
Previously VOSPD value was limited to 120% of Vmax now this limit is removed. Not Used. |
SYNC |
Error |
|
3085 |
Incorrect parameter value |
当用户给定的参数不在允许的参数范围内时,返回一般错误。 |
SYNC |
错误 |
|
3086 |
Incorrect number of point coordinates given to this movement |
在给定的组(不要与关节混淆)运动命令如:MOVE,MOVES,...目标点师必须有精确的坐标数(等于组中的轴数) |
SYNC |
错误 |
|
3087 |
Target position will exceed the limit |
Used in group CIRCLE command if the final position obtained from the starting point after rotation by the given circle angle exceeds the position limit on any of the group's axes.Not Used. |
SYNC |
Error |
|
3088 |
Wrong factor value : specify a positive value |
有些值 (PFAC, AFAC, VFAC, ....)不能是负数 |
SYNC |
错误 |
|
3089 |
Property value cannot be changed while drive is enabled |
某些属性(如转换系数)在驱动器使能时不能更改。有关指令执行的限制,请参阅参考手册。 |
SYNC |
错误 |
Idle Task |
3090 |
Can not execute syncstart without any pending move command |
SYNCStart中没有定义运动的错误 |
SYNC |
错误 |
|
3091 |
Drive mode failure (unable to set drive-mode) |
N/A for MC |
N/A |
N/A |
|
3092 |
Property can not be changed while cam is active : disable cam before changing it |
凸轮表处于活动状态时,某些凸轮属性不能更改。 |
SYNC |
错误 |
|
3093 |
Invalid hard limit switch state |
N/A for MC |
N/A |
N/A |
|
3094 |
Hard limit switch was detected |
N/A for MC |
N/A |
N/A |
|
3095 |
The cruise velocity can not be reached |
串联期间(vifnal非零) |
SYNC |
Note |
|
3096 |
Minimum position limit must be less than the maximum limit |
PMIN必须小于PMAX |
SYNC |
错误 |
|
3097 |
Data structure is not defined. |
补偿或凸轮表未定义 |
SYNC |
错误 |
|
3098 |
VelocityMax exceeds the max number of counts per motion sample. Reduce VelocityMax or change PositionFactor - VelocityFactor settings. |
|
SYNC |
Error |
|
3099 |
Cannot execute InPosition |
当前一个运动的最终速度非零时,STARTTYPE的INPOSITION值是没有意义的。 |
SYNC |
Note |
|
3100 |
Configuration switch. |
N/A for MC |
N/A |
N/A |
|
Number |
Message |
Description |
Type |
Severity |
Action |
3101 |
Time jog is meaningless |
TimeJog can not be zero. |
SYNC |
Note |
|
3102 |
The index is out of the table range. |
The index is out of the cam table range. This error is returned when attempting to access a value in the cam table, where the index is greater than the number of points in the table. |
SYNC |
Error |
|
3103 |
Given value will cause cam table to be non-monotonic: value not accepted. |
The cam table is chained, but the data are not in use. The given value for the master would cause the table to be non-monotonic, so the value is not accepted. |
SYNC |
Note |
|
3104 |
The movement will be calculated until the position limit |
|
SYNC |
Note |
|
3105 |
Blending is not provided with non-zero final velocity motions and jog movements |
vfinal = .. and cp = … can not work together |
SYNC |
Error |
|
3106 |
Invalid Quaternion. |
internal error, mostly in SCARA &DELTA kinematics when orientation with non-zero yaw and pitch is obtained |
SYNC |
Error |
|
3107 |
Initialized the velocity to its maximum |
If Vcruise > vmax the vmax will be taken. |
ASYNC |
Note |
|
3109 |
Wrist configuration at the target point differs from the wrist configuration of the start! |
during movement path passes wrist singular and the wrist changes its flip value, therefore the target position can differ from its pre-computed value and a recalculation note can occur |
ASYNC |
Note |
|
3110 |
Wrong Phaser definition. |
phaser parameters are invalid |
SYNC |
Error |
|
3111 |
Wrist Singularity encountered. Motion has been stopped. Try with different movement type |
untreatable wrist singularity |
ASYNC |
Note |
|
3112 |
Initialized the acceleration to its maximum |
If acc > amax the amax will be taken. |
ASYNC |
Note |
|
3113 |
Initialized the deceleration to its maximum |
If dec > dmax the dmax will be taken. |
ASYNC |
Note |
|
3114 |
Initialized the jerk to its maximum |
If jerk> jmax the jmax will be taken. |
ASYNC |
Note |
|
3115 |
Element entered into following mode, all motions aborted |
An active motion was aborted due to element's disable |
SYNC |
Error |
|
3116 |
The configuration flags can not be specified together with joint target position. |
giving both joint target coordinates and configuration flags is not possible. |
SYNC |
Error |
|
3117 |
Point too close. The target coordinates are too close to the robot's Cartesian space origin point. |
the target point is inside Rmin sphere (or XY circle only in case of PUMA) |
SYNC |
Error |
|
3118 |
MOVES can not interpolate these orientation angels. Try with different orientation interpolation or change the target to location. |
Some orientation path can not be proportionally interpolated together with the translational part as the joint angles needed for translation conflicts the given orientation component. |
SYNC |
Error |
|
3119 |
Point too far. Outside of the working envelope. The target coordinates are too far from the robot's Cartesian space origin point. |
the target point is outside Rmax sphere |
SYNC |
Error |
|
3120 |
Not a robot. |
Certain properties are fro robot models only and do not exist in regular groups |
SYNC |
Error |
|
3121 |
The target point is not reachable. |
Target coordinate exceed [pmin,pmax] segment |
SYNC |
Error |
|
3122 |
Motion can not be executed due to the unsolvable configuration change. |
During straight line motion some start and target configuration flags can not differ (ABOVE, BELOW) |
SYNC |
Error |
|
3123 |
Unreachable target orientation. |
Internal checking of quaternion. In some robot models (SCARA, DELTA< ….) NDOF of orientation representation is limited therefore the quaternion of target orientation ahs to obey certain restrictions. Normally user can not produce this error. |
SYNC |
Error |
|
3124 |
Crossing unreachable region. |
For example in SCARA straight line motion that crosses Rmin sphere is not allowed |
SYNC |
Error |
|
3125 |
Wrong point type. |
Location point type does not fit to the given command/property. |
SYNC |
Error |
|
3126 |
Can not de-select orientation coordinates. Check the selectaxis property |
N/A for MC |
N/A |
N/A |
|
3127 |
Both final velocities(rotary & translation) must be zero or non zero |
vtranfinal and vrotfinal can either be both zero or both non-zero. |
SYNC |
Error |
|
3128 |
Error in Closed-Chain Kinematics. Point is not reachable |
joint coordinates do not close the close-chain kinematics (happens only in certain models s: SCISSOR, CSE, …) |
ASYNC |
Error |
|
3129 |
Task start failure. |
Internal Error. Cannot start the task. The error is returned from the operating system. |
SYNC |
Fatal Fault |
|
3130 |
Task end failure. |
Internal Error. Cannot end the task. The error is returned from the operating system. |
SYNC |
Fatal Fault |
|
3131 |
Invalid semaphore ID or time-out elapsed. |
Internal Error. Invalid semaphore ID. The error is returned from the operating system. |
SYNC |
Fatal Fault |
|
3132 |
Invalid message. |
Internal Error. Invalid message received by the motion manager. The motion manager is a message-driven task. Receiving an invalid message is a fatal system fault. |
SYNC |
Fatal Fault |
|
3133 |
Invalid element handle. |
Internal Error. Invalid element handle encountered during the real time execution. The error is identical to the MOT_ERR_IELEMENT but this time the source is internal (not the interpreter) |
ASYNC |
Fatal Fault |
|
3134 |
No memory. |
Internal Error. No more free memory in the system. The memory of the system is exhausted. The memory for the motion should always be available. |
SYNC |
Fatal Fault |
|
3135 |
Invalid pointer. |
Internal Error. Invalid pointer encountered during the real-time execution. A zero pointer was found in the RTK or MM task. |
SYNC |
Fatal Fault |
|
3136 |
Corrupted task data. |
Internal Error. Invalid task data. Each attached task is represented by a block of data. If these data are corrupt, a fatal system error occurs. |
SYNC |
Fatal Fault |
|
3137 |
Task mismatch. |
Internal Error. A task tried to add an axis to the group that it did not create. Group creation is a process of several steps and during this process only the task that started creation of the group can end it. |
SYNC |
Fatal Fault |
|
3138 |
Bad dimension. |
Internal Error. The element dimension (number of axes) is invalid. Each motion package contains the size (dimension) of the group. If a copy of two packages with different dimensions was ordered, this fatal error is generated. |
SYNC |
Fatal Fault |
|
3139 |
Corrupted data |
Internal Error. During the element deletion procedure, corrupt data were encountered. When the element data are de-allocated, a number of checks are conducted. Among the checks is verification that all allocated motion packages are deleted. If not, the error is set. |
SYNC |
Fatal Fault |
|
3140 |
RTS blocked. |
Internal Error. The RTS did not release the semaphore. The RTS releases this semaphore periodically, but if the semaphore is not released after two time periods, this error is set. It indicates the RTS is not functioning properly or that the interrupt handler stopped. |
ASYNC |
Fatal Fault |
|
3141 |
Bad profile data. |
Internal Error. Profiler error. Invalid data for the profile calculation given. |
SYNC |
Fatal Fault |
|
3142 |
RTS element add failed. |
Internal Error. The RTS failed to add an element. The RTS refused to add new element in its table. |
SYNC |
Fatal Fault |
|
3144 |
RTS clear motion failed. |
Internal Error. The RTS failed to clear the motion enable flag. The error can occur during the RTK initialization or during the suspend-resume transitions. |
ASYNC |
Fatal Fault |
|
3145 |
RTS set motion failed. |
Internal Error. The RTS failed to set the motion enable flag. The error can occur during the RTK initialization or during the suspend-resume transitions. |
ASYNC |
Fatal Fault |
|
3146 |
RTS overrun clear failed. |
Internal Error. The RTS failed to clear the overrun flag. Occurs only in run time. |
SYNC |
Fatal Fault |
|
3147 |
RTS delete failed. |
Internal Error. The RTS failed to delete an element. At the end of the deletion task, the system failed to delete the RTS entry. Recovery action is not needed because the task is dead. |
SYNC |
Fatal Fault |
|
3148 |
Computing too late |
The pre-computation is late. For immediate motion changes such as immediate move or speed override, a pre-computation time delay is assumed. Normally, this delay should be sufficient to complete computation. This error generally indicates that the system is too heavily loaded. |
ASYNC |
Error |
|
3149 |
Unable to create system resource. |
Internal Error. The operating system is unable to create the resource (Queue, Semaphore, ...) Possible cause: No more memory, operating system down. |
SYNC |
Fatal Fault |
|
3150 |
Invalid profiler parameters. |
Internal Error. Invalid profiler parameters. |
Sync |
Fatal Fault |
|
3151 |
Profiler in motion. |
Internal Error. Certain profiler settings can only be set when the acceleration is zero. |
SYNC |
Fatal Fault |
|
3152 |
Invalid profiler status. |
Internal Error. The profiler is state driven. If an invalid status is encountered, this error occurs. |
SYNC |
Fatal Fault |
|
3153 |
RTK continuously interrupting. |
Internal Error. The RTK is in a continuously repeating stop state. |
ASYNC |
Fatal Fault |
|
3154 |
Maximum Position reached. |
Maximum axis limit reached. Usually by a JOG command. |
SYNC |
Error |
|
3155 |
Minimum position reached |
Axis minimum limit reached. Usually by a JOG command. |
SYNC |
Error |
|
3156 |
No previous package. |
Internal Error. In the pre-calculation process a pointer of the previous package in the m.p. ring is needed. |
SYNC |
Fatal Fault |
|
3157 |
Supper-immediate movements can be executed with the trapezoidal velocity profile only. |
with starttype = 5 smooth must be equal 0 |
SYNC |
Error |
|
3158 |
Property value cannot be changed while drive is disabled |
Certain properties (slave, ...) can not be changed to certain values if the drives are disabled. Same with certain commands (proceed, move, ...) . |
SYNC |
Error |
|
3159 |
No memory for group/axis definition |
No more free memory in the system. The memory of the system is exhausted. |
SYNC |
Error |
|
3160 |
Wrong PLS index. |
Wrong PLS index. |
SYNC |
Error |
|
3161 |
Can't declare more PLS's |
A maximum of 65536 PLS can be declared. |
SYNC |
Error |
|
3162 |
PLS property cannot be set while PLS is enabled |
Certain PLS properties cannot be set while the PLS is enabled. First, disable the PLS, then change the property value. |
SYNC |
Error |
|
3163 |
PLS value cannot be accessed before the PLS data are created |
In order to operate on a PLS, the PLS must be defined (COMMON SHARED ... AS PLS), and the PLS data must be created (CREATEPLSDATA). |
SYNC |
Error |
|
3164 |
PLS position index out of range |
This error is returned when attempting to access a non-existent PLS position. The number of PLS positions is set when creating the PLS data structure (CREATEPLSDATA). |
SYNC |
Error |
|
3165 |
PLS position data must be monotonic |
The data in the PLS data structure must be arranged in ascending order. The order is verified when attempting to enable the PLS. |
SYNC |
Error |
|
3166 |
PLS output polarity must be binary (0 / 1) |
The PLS output polarity must be binary(0 or 1). |
SYNC |
Error |
|
3167 |
Wrong value for the repetition interval. |
Wrong value for the repetition interval. |
SYNC |
Error |
|
3168 |
PLS Enable must be binary ( 0 or 1 ) |
The PLS Enable must be binary (0 or 1). |
SYNC |
Error |
|
3169 |
Fatal Fault, the error number is not defined by the programmer |
Internal error |
SYNC |
Fatal Fault |
Watch dog |
3170 |
PLS Hysteresis must be positive |
The value specified for the PLS, hysteresis must be positive. |
SYNC |
Error |
|
3171 |
PLS cannot be deleted while it is enabled |
PLS cannot be deleted while it is enabled. First disable the PLS using the PLSENABLE property. |
SYNC |
Error |
|
3172 |
Wrong output index. |
Wrong output index. |
SYNC |
Error |
|
3173 |
Cannot attach element. Element is stopped by another task: issue PROCEED command |
The STOP command is used both to stop motion and to inhibit further motion. If the STOP command has been issued from the terminal or a task, then the motion element cannot be attached by another task until the PROCEED command has been issued. |
SYNC |
Error |
|
3174 |
Current property cannot be changed for a Master axis |
Current property of an axis that is defined as a master axis cannot be changed. First disable the master/slave by setting the slave property of the slave axis to OFF. |
SYNC |
Error |
|
3175 |
Wrong index for location. |
Querying coordinates of location variables like here,setpoint, tool, etc. an index outside [1,NDOF] was given. |
SYNC |
Error |
|
3176 |
PLS value will is scaled to be at the range 0-100%. |
N/A for MC |
N/A |
N/A |
|
3177 |
Cannot execute the move command while the axis is active in a group |
Axis can not be moved separately if its' group is attached. For example MOVE AX1 ... is not allowed if G1 having AX1 is attached. |
SYNC |
Error |
|
3178 |
Cannot execute the stop command while the axis is active in a group |
Axis can not be stopped independently from its group. |
SYNC |
Error |
|
3179 |
Cannot move immediate. Need to proceed motion |
Element that was stopped can not executed immediate motion (StartType=1) until it is proceeded. |
SYNC |
Error |
|
3181 |
Index out of range |
Link[] or Axis[] wrong index |
SYNC |
Error |
|
3182 |
Disable time out expired: NETWORK SHUTDOWN |
Disable timeout of the drives expired |
SYNC |
Error |
|
3183 |
Settling time expired |
Timeout for achieving position expired |
SYNC |
Error |
|
3184 |
Maximum trial time to settle is less than settling time |
Maximum trial time to settle is less than settling time |
SYNC |
Error |
|
3185 |
Ambiguous configuration flags. Can not determine the joint coordinates. |
N/A for MC |
N/A |
N/A |
|
3186 |
Motion Buffer Full |
There are already two motions pending in the motion buffer. |
SYNC |
Error |
|
3187 |
Could not interpolate in Cartesian space with this target point. Try to re-write the target point or change the motion. |
A straight line movement with joint target values did not reach the given target joint coordinates, most probably there is an issue with orientation angels. |
ASYNC |
Error |
|
3188 |
Insufficient points during dynamic AI |
Not enough point for Advanced Interpolation |
SYNC |
Error |
|
3191 |
Pipe Mode operation failed. |
Error reading values during the pipe mode |
ASYNC |
Error |
|
3192 |
Element is not attached |
Trying from a task to change a property or to move an element that is not attached to that task. |
SYNC |
Error |
|
3193 |
The user limit can not exceed the max/min limits. |
N/A for MC |
N/A |
N/A |
|
3194 |
The max/min limits can not be set within the user limits. |
N/A for MC |
N/A |
N/A |
|
3195 |
Element Pipe Mode is declared or system Pipe Mode is disabled. |
|
SYNC |
Error |
|
3196 |
Wrong factor value: specify a non zero value |
Wrong factor value: specify a non zero value |
SYNC |
Error |
|
3197 |
Displacement cannot be set if PLS enabled. |
|
SYNC |
Error |
|
3199 |
Value can't be changed from terminal |
slave=5 can be given from program only |
SYNC |
Error |
|
3200 |
This motion interpolation type must have a non-zero translation part |
in CIRCLE motion type motions with only orientation part are not allowed. |
SYNC |
Error |
|
Number |
Message |
Description |
Type |
Severity |
Action |
3201 |
At circular movement first 2 axes must be linear. Check value of PositionRollOverEnable |
if issuing circle on XY tables (for examples) rollover must be disabled |
SYNC |
Error |
|
3202 |
The group is not coupled |
|
N/A |
N/A |
|
3203 |
The coupled matrix has been changed or its inverse doesn't exist |
|
N/A |
N/A |
|
3204 |
Inverse matrix can not be calculated |
When giving circle motion using three points or when defining coupling matrix |
SYNC |
Error |
|
3205 |
Memory allocation for matrix failed |
When giving circle motion using three points or when defining coupling matrix |
SYNC |
Error |
|
3206 |
Wrong matrix dimension |
When giving circle motion using three points or when defining coupling matrix |
SYNC |
Error |
|
3207 |
Property valid for Group only |
Some properties are not defined for axes |
SYNC |
Error |
|
3208 |
Blending omitted due to stopped motion |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3209 |
Blending omitted due to braking motion |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3210 |
Blending omitted due to short path |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3211 |
Blending omitted due to missing cruise phase |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3212 |
Blending omitted due to different motion types |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3213 |
Blending omitted due to extremely short motion duration |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3214 |
Blending: acceleration decreased due to exceeding total acceleration |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3215 |
Blending: velocity decreased due to exceeding total velocity |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3216 |
Blending: velocity decreased due to profiler following |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3217 |
Blending: acceleration decreased due to profiler following |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3218 |
Blending: jerk decreased due to profiler following |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3219 |
Blending: acceleration decreased due to short braking distance |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3220 |
Blending: jerk decreased due to short braking distance |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3221 |
Blending: velocity & jerk decreased for adjusting to the profiler following |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3222 |
Blending: Second velocity reduced |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3223 |
Blending: First velocity reduced |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3224 |
Blending: First marker set |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3225 |
Blending: Second marker set |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3226 |
Blending omitted due to inability to adjust velocity for the given blending distance and cruise velocity |
|
SYNC |
Note, activated using sys.motionassistance =1 only |
|
3227 |
Wrong moving frame index |
Translator givens an non-existent handle, or generic moving frame is not defined |
SYNC |
Error |
|
3228 |
There isn't any moving frame linked |
No moving frame is linked to the robot. |
SYNC |
Error |
|
3229 |
Can't declare more moving frames |
Maximum number of moving frames in the system exceeded |
SYNC |
Error |
|
3230 |
Invalid index or ndf. Moving frame NDOF range is 1 to element NDOF |
|
SYNC |
Error |
|
3231 |
The element is already in tracking mode |
N/A for MC |
N/A |
N/A |
|
3232 |
The moving frame is already linked to an element |
Certain actions of setting moving frame properties are not allowed while the moving frame is linked to a robot |
SYNC |
Error |
|
3233 |
Robot type and moving frame type must be the same |
same robot type of the moving frame and the robot is mandatory |
SYNC |
Error |
|
3234 |
No more triggers can be inserted |
Max number of triggers exceeded |
SYNC |
Error |
|
3235 |
The moving frame must be linked to a Robot. |
Certain actions are not allowed if the moving frame is not linked to a robot |
SYNC |
Error |
|
3236 |
Working window limits are too close - check upmaster & downmaster values |
|
SYNC |
Error |
|
3237 |
No more triggers in the buffer. |
this error is caused when applying NextItem command when there is nothing in the conveyorTracking buffer |
SYNC |
Error |
|
3238 |
Item missed. The item has left the working-window area. |
|
SYNC |
Error |
|
3239 |
Blending: CP of the first movement reduced due to the big velocity ratio |
|
N/A |
N/A |
|
3240 |
Property valid for axis only |
Some motion element properties are valid for axes only. Examples are PFAC, PEXT. |
SYNC |
Error |
|
3241 |
Delay cannot be used with the StartType set to Immediate. |
The DELAY command is subject to the STARTTYPE of the motion element being delayed. However, using STARTTYPE Immediate with the DELAY command is not allowed. Change STARTTYPE before executing the DELAY command. |
SYNC |
Error |
|
3242 |
No possibility for blending of different profile types |
CP blending of trapezoidal velocity and sine profile is not allowed |
SYNC |
Error |
|
3243 |
Stop in progress. |
Certain very special cases of motion are not allowed to be given while motion is stopping. |
SYNC |
Error |
|
3244 |
Cannot change following mode while homing is in progress |
mode can be set only while motion is stopped |
SYNC |
Error |
|
3245 |
Error in homing procedure |
|
ASYNC |
Error |
|
3246 |
Axis position after homing is subjected to the axis displacement |
N/A for MC |
N/A |
N/A |
|
3247 |
System Motion property can be set only from the terminal |
The default system error handler sets the system motion flag low. Once this happens, the MOTION property can be set high only when SYSTEM.MOTION=ON is issued form the terminal. |
SYNC |
Error |
|
3248 |
This motion interpolation type is not allowed. |
The given interpolation type is not allowed. (joint interpolation during conveyor tracking, MOVESKD on certain robot models, jointEnable property is false ... |
SYNC |
Error |
|
3249 |
System automatic braking |
The velocity is not zero. The element is stopped by the system. This can occur when a slave axis has passed its position limits. The axis is then stopped by the system. |
ASYNC |
Fatal Fault |
|
3250 |
Different motion type in group |
The group can only be defined if the axes are of the same type. The error occurs during the group definition or when the system or user tries to attach the group. Motion types are LINEAR or ROTARY. |
SYNC |
Error |
|
3251 |
RTS set motion failed in initialization. |
Internal error. The RTS failed to set the motion enable flag. The error occurs during the RTK initialization or during the suspend-resume transitions. |
ASYNC |
Fatal Fault |
|
3252 |
RTS clear motion failed in initialization. |
Internal error. The RTS failed to clear the motion enable flag. The error occurs during the RTK initialization or during the suspend-resume transitions. |
ASYNC |
Fatal Fault |
|
3253 |
Following error when motion is stopped: drive disabled. |
There is no motion commanded, but there is a position error. The maximum position error (PEMax) may be set too low, or the axis may be moved by an external force, or the drive may not be tuned properly. |
ASYNC |
Error |
|
3254 |
Envelope error when motion is stopped: drives disabled. |
There is no motion commanded, but there is an envelope error. The maximum position error (PEMAX) may be set too low, the axis may be moved by an external force, or the drive may not be tuned properly. |
ASYNC |
Error |
|
3255 |
Fatal experience |
should never happen |
SYNC |
Fatal Fault |
|
3256 |
The acceleration/deceleration time is not achieved |
tacc/tdec values not achieved |
SYNC |
Note |
|
3257 |
Homing is not allowed on a slaved axis |
|
SYNC |
Error |
|
3258 |
No home input assigned |
|
SYNC |
Error |
|
3259 |
Drive parameters are zeroed |
N/A for MC |
N/A |
N/A |
|
3260 |
Value assigned was rounded up to nearest integer |
|
N/A |
N/A |
|
3261 |
Invalid moving frame parameters. |
zero radius, zero angle or identical up & down points |
SYNC |
Error |
|
3262 |
Compensation table table is empty. |
|
SYNC |
Error |
|
3263 |
Can't declare more compensation tables. |
Maximum number of compensation tables exceeded |
SYNC |
Error |
|
3264 |
Invalid compensation table index |
Compensation Handle received from translator is invalid, either internal interpreter error or usage of generic compensation table that is not defined |
SYNC |
Error |
|
3265 |
Compensation table active value must be set to 0 or 1. |
0/1 only allowed here |
SYNC |
Error |
|
3266 |
Compensation table can not be changed while in use: value not accepted. |
|
SYNC |
Error |
|
3267 |
Load the compensation table data and set the axes(function compset) first. |
|
SYNC |
Error |
|
3268 |
Number of axes does not match the mechanical model |
Robot models can be defined only with certain number of axes |
SYNC |
Error |
|
3269 |
Position command might be lost by this action |
N/A for MC |
N/A |
N/A |
|
3270 |
Velocity rate initialized to its limit |
rate values allowed in [0.1,100] percents range only |
SYNC |
Note |
|
3271 |
Acceleration rate initialized to its limit |
rate values allowed in [0.1,100] percents range only |
SYNC |
Note |
|
3272 |
Deceleration rate initialized to its limit |
rate values allowed in [0.1,100] percents range only |
SYNC |
Note |
|
3273 |
Jerk rate initialized to its limit |
rate values allowed in [0.1,100] percents range only |
SYNC |
Note |
|
3274 |
After digital torque command only supper immediate movement is allowed |
N/A for MC |
N/A |
N/A |
|
3275 |
The property can not be queried if no tracking (slave <>0) has been established. |
|
SYNC |
Error |
|
3276 |
Element is detached by the system in order to avoid endless error messaging. |
In certain case (error in closed chain kinematics induced by joint angles) the group is detached automatically |
ASYNC |
Note |
detach |
3277 |
Absolute motion not allowed |
AbsEnable is zero |
SYNC |
Error |
|
3278 |
Wrong buffer size. |
AI: Pass command with an array bigger then AI buffer |
SYNC |
Error |
|
3279 |
The correct setting is: passbuffermin < passbuffermax < passbuffersize. |
AI: Check PassBufferMin, PassBufferMax, …. |
SYNC |
Error |
|
3280 |
Wrong stretch factor value. |
percents inside [0.1,100] allowed only |
SYNC |
Error |
|
3281 |
Wrong size of stretch factor vector or user parameter vector. |
AI: Pass command with an array bigger then AI buffer |
SYNC |
Error |
|
3282 |
Wrong relationship between passfrom and passupto properties. |
passfrom must be always less than passupto |
SYNC |
Error |
|
3283 |
No more points to interpolate. |
DOPASS issued on an empty buffer. |
SYNC |
Note |
|
3284 |
Wrong blend method. |
AI is not allowed with CP or SP blending |
SYNC |
Error |
|
3285 |
Advance interpolation/Conveyor tracking cannot be used with starttype immediate. |
AI is not allowed with CT |
SYNC |
Error |
|
3286 |
Advance interpolation - points have been lost. |
Point buffer cleared (stop, reset of BlendingMethod property) no proceed of the stopped motion possible |
Note |
Error |
|
3287 |
Excessive master-slave deviation |
|
SYNC |
Error |
stop |
3288 |
Number of axes does not match the given compensation table dimensions. |
|
SYNC |
Error |
|
3289 |
Action not allowed while compensation table is active. |
|
SYNC |
Error |
|
3290 |
Compensation table: Limit mismatch. |
|
SYNC |
Error |
|
3291 |
This compensation table has been already set. |
|
SYNC |
Error |
|
3292 |
No more space for compensation tables. |
|
SYNC |
Error |
|
3293 |
Compensation table: Invalid row. |
|
SYNC |
Error |
|
3294 |
Velocity Safety Limit exceeded! |
A drastic increase(jump) of pcmd during one sample exceeds the VelocitySafetyLimit of that axis. The VelocitySafetyLimit should be set at least to a 10*Vmax of the same axis. See: VelocitySafetyLimit . |
ASYNC |
Fatal Fault |
|
3295 |
Extremely low velocity. |
JOG 0 is not allowed |
SYNC |
Error |
|
3296 |
Additive torque value is over threshold limit |
TorqueAddCommand > Tmax |
ASYNC |
Error |
stop |
3297 |
Additive torque value is over threshold limit when motion is stopped: drive disabled |
TorqueAddCommand > Tmax |
ASYNC |
Error |
disable |
3298 |
The pls positions are too close to each other and/or the velocity is too high for output to toggle |
|
ASYNC |
Error |
|
3299 |
Hardware Assistance is true but not available due to wrong CPU/FPGA/etc. |
|
SYNC |
Error |
|
3300 |
Excessive master-slave deviation when the motion is stopped: drive disabled |
|
ASYNC |
Error |
disable |
Number |
Message |
Description |
Type |
Severity |
Action |
4001 |
Error opening file for Retrieve |
Error opening file for RETRIEVE |
SYNC |
Error |
|
4002 |
Error opening the file for Send |
Error opening the file for SEND |
SYNC |
Error |
|
4003 |
Internal error. Contact technical support. |
Internal Error. Creating message pipe for upload. |
SYNC |
Error |
|
4004 |
Internal error. Contact technical support. |
Internal error. Creating message pipe for download. |
SYNC |
Error |
|
4005 |
Internal error. Contact technical support. |
Internal error. Removing message pipe for upload. |
ASYNC |
Error |
|
4006 |
Internal error. Contact technical support. |
Internal error. Removing message pipe for download. |
ASYNC |
Error |
|
4007 |
Internal error. Contact technical support. |
Internal error Upload task exists. |
SYNC |
Error |
|
4008 |
Internal error. Contact technical support. |
Internal error. Download task exists. |
SYNC |
Error |
|
4009 |
Internal error. Contact technical support. |
Internal error. Creating upload task. |
SYNC |
Error |
|
4010 |
Creating download task |
Internal error. |
SYNC |
Error |
|
4011 |
Internal error. Contact technical support. |
Internal error. Cannot create RAM drive device. |
ROOT |
Fatal Fault |
Watchdog |
4012 |
Internal error. Contact technical support. |
Internal error. Bad initialization option. |
SYNC |
Error |
|
4013 |
No memory for RAM drive volume |
There is not enough memory to create the RAM disk. Add more memory or delete unneeded files. |
SYNC |
Error |
|
4014 |
Time-out during file transfer |
Host has interrupted file transfer operation. |
ASYNC |
Note |
|
4015 |
No disk space |
File operation could not be accomplished due to the lack of disk space. |
SYNC |
Error |
|
4016 |
File not found |
Cannot locate the file. |
SYNC |
Error |
|
4017 |
Error opening file |
Error opening file. |
SYNC |
Error |
|
4018 |
Error closing file |
Error closing file. |
SYNC |
Error |
|
4019 |
Disk full |
There is no free disk space on the file device. |
SYNC |
Error |
|
4020 |
Invalid device name |
Invalid device name specified for the file operation. |
ROOT |
Fatal Fault |
Watchdog |
4021 |
Cannot delete file. |
There is no permission to delete the file. |
SYNC |
Error |
|
4022 |
Cannot delete directory. Use RMDIR. |
Trying to delete directory. |
SYNC |
Error |
|
4023 |
Cannnot delete directory - it is not empty or in use. |
Cannot delete directory because it is not empty |
SYNC |
Error |
|
4024 |
Error reading directory |
An error occurred while executing DIR |
SYNC |
Error |
|
4025 |
Cannot create directory - it already exists or access is denied. |
Cannot create directory. |
SYNC |
Error |
|
4026 |
Closing directory |
An error occurred during execution of the DIR command |
SYNC |
Error |
|
4027 |
Memory allocation error. |
Cannot allocate internal data structure. Add more memory or unload tasks that are not needed. |
SYNC |
Error |
|
4028 |
Error writing into file |
Error writing into a file. |
SYNC |
Error |
|
4029 |
Error reading from file |
Error reading from a file. |
SYNC |
Error |
|
4030 |
Bad access to the file |
Invalid pointer to the file handle. |
SYNC |
Error |
|
4031 |
Unknown file extension. |
Only specific file extensions are recognized. These are PRG for programs, REC for record files CAM for cam files. |
SYNC |
Error |
|
4032 |
Cannot access this type of file |
Access to this type of file is not permitted by the system. |
SYNC |
Error |
|
4033 |
File does not exist |
This message is given when trying to operate on (RETRIEVE, DELETE, LOAD) a file that does not exist on the flash disk. |
SYNC |
Error |
|
4034 |
Root directory is full |
The number of files in the root directory has reached the maximum number of files allowed. |
SYNC |
Error |
|
4035 |
Invalid semaphore ID |
Invalid semaphore ID. The semaphore guards linked list of the files. |
SYNC |
Fatal Fault |
|
4036 |
Password file is broken. |
Failed to initiate the password list – password file is not valid. |
ASYNC |
Error |
|
4037 |
Invalid password. |
Invalid password entered. |
SYNC |
Error |
|
4038 |
Password protected |
The file cannot be deleted or retrieved because it is protected by a password. Use the PROGRAMPASSWORD command to remove the protection. |
SYNC |
Error |
|
4039 |
Error setting the password |
Cannot write into the system password's log. |
SYNC |
Error |
|
4040 |
File in use. Access denied. |
A file with same name already has been opened. If it was open for reading you cannot open it for writing. |
SYNC |
Error |
|
4041 |
No available file descriptors |
No file descriptors available at the current directory. |
SYNC |
Error |
|
4042 |
Illegal name |
The file name is illegal from the File system's point of view. |
SYNC |
Error |
|
4043 |
Cannot rename. Files are on different devices. |
File rename failed – the extension is allocated to a different device (RAM drive or system devices). |
SYNC |
Error |
|
4044 |
Cannot rename. Destination file already exists. |
File rename failed – a duplicate file name exists. |
SYNC |
Error |
|
4045 |
Cannot rename file. |
File rename failed – file in use. |
SYNC |
Error |
|
4048 |
Directory does not exist. |
Internal error: directory does not exist. |
SYNC |
Error |
|
4049 |
Cannot create sub-directory - only 17 levels are allowed. |
Cannot create sub-directory - only 17 levels are allowed. |
SYNC |
Error |
|
4050 |
Volume unavailable. |
Volume not available. |
SYNC |
Error |
|
4051 |
Internal file system error |
Internal error. |
SYNC |
Error |
|
4052 |
Error opening directory. |
An error occurred while accessing a directory. |
SYNC |
Error |
|
4053 |
Firmware upgrade failure - current firmware version is not the new one. |
Upgrade failed - either cannot delete or cannot rename files. File(s) may be write protected |
SYNC |
Error |
|
4054 |
Firmware restoration failed - current firmware version is not the previous one. |
Cannot copy backup file. Possibly not enough disk space or file(s) is write protected. |
SYNC |
Error |
|
4055 |
Error creating a contiguous boot file. |
There is not enough space on Flash or hard disk for contiguous bootrom. |
SYNC |
Error |
|
4056 |
Error creating TFFS block device. |
Not used |
N/A |
N/A |
|
4057 |
Cannot install file system driver. |
Not used |
N/A |
N/A |
|
4058 |
No memory to create disk cache. |
Out of RAM |
ROOT |
Fatal Fault |
|
4059 |
No memory to create file system device. |
Out of RAM |
ROOT |
Fatal Fault |
|
4060 |
NVRAM data checksum error. |
Data on the NVRAM is corrupted. Perform NVRAMFORMAT to overcome this problem. |
SYNC |
Error |
|
4061 |
Error creating semaphore. |
Internal error. Failure to create Semaphore during initialization of the NVRAM module. |
ASYNC |
Error |
|
4062 |
Variables indexes exceed the size of NVRAM. |
NVRAMFORMAT command failed while trying to define an NVRAM array that is larger than the NVRAM size. |
SYNC |
Error |
|
4063 |
Value is out of range. |
Index value is out of range. |
SYNC |
Error |
|
4064 |
NVRAM does not exist. |
The controller does not have an NVRAM device. |
SYNC |
Error |
|
4065 |
Unknown error |
An unknown error code was generated while the file system was in operation. |
SYNC |
Fatal Fault |
|
Number |
Message |
Description |
Type |
Severity |
Action |
5001 |
Internal error. Contact technical support. |
Internal error. Contact technical support. |
ROOT |
Fatal Fault |
Watchdog |
5002 |
Failed to create output pipe: add more memory. |
Failed to create pipe. Add more memory. |
ROOT |
Fatal Fault |
Watchdog |
5003 |
Internal error. Contact technical support. |
Internal error. Contact technical support. |
ROOT |
Fatal Fault |
Watchdog |
5004 |
Failed to create input task: add more memory. |
Not enough memory to create task. Add more memory |
ROOT |
Fatal Fault |
Watchdog |
5005 |
Failed to create output task: add more memory. |
Not enough memory to create task. Add more memory |
ROOT |
Fatal Fault |
Watchdog |
5006 |
Failed to create semaphore: add more memory. |
Failed to create sync semaphore. Add more memory. |
ROOT |
Fatal Fault |
Watchdog |
5007 |
Internal error. Contact technical support. |
Internal error. Contact technical support |
ROOT |
Fatal Fault |
Watchdog |
5008 |
Internal error. Contact technical support. |
Internal error. Contact technical support |
ROOT |
Fatal Fault |
Watchdog |
5009 |
Serial communication error; Bad BCC. Try again |
Failed to match Block control character in message. |
ASYNC |
Error |
|
5010 |
Serial communication error; Bad protocol data. Try again |
Failed to detect new line in message. |
ASYNC |
Error |
|
5011 |
Serial communication error; Bad protocol data format: try again |
Failed to format output message. |
ASYNC |
Error |
|
5012 |
Failed to write translator input. |
Memory exhausted on RAM drive. Add memory or delete REC files. |
Terminal |
Error |
|
5013 |
Internal error. Contact technical support |
Internal error. Contact technical support |
Terminal |
Error |
|
5014 |
Internal error. Contact technical support |
Internal error. Contact technical support |
Terminal |
Error |
|
5015 |
Failed to create semaphore: add more memory |
Failed to create mutex for active context. Add more memory. |
ROOT |
Fatal Fault |
Watchdog |
5016 |
Internal error. Contact technical support |
Internal error. Contact technical support |
Terminal |
Error |
|
5017 |
Internal error. Contact technical support |
Internal error. Contact technical support |
Terminal |
Error |
|
5018 |
Internal error. Contact technical support |
Internal error. Contact technical support. |
Terminal |
Error |
|
5019 |
Internal error. Contact technical support |
Internal error. Contact technical support |
Terminal |
Error |
|
5020 |
Failed to create internal file: add more memory. |
Failed to create back-end output file. Add more memory. |
ROOT |
Fatal Fault |
Watchdog |
5021 |
Internal error. Contact technical support |
Failed to create memory device. |
ROOT |
Fatal Fault |
Watchdog |
5022 |
Virtual input index out of range |
Virtual input is out of range. Refer to SYS.VIN in Reference Manual. |
SYNC/ ASYNC |
Error |
Idle Task |
5023 |
Virtual output index out of range |
Virtual output is out of range. Refer to SYS.VOUT in Reference Manual. |
SYNC/ ASYNC |
Error |
Idle Task |
5024 |
Fast data available for axes 1 through 8 only |
Fast Data may be enabled only for axes 1 through 8. |
SYNC |
Error |
Idle Task |
5025 |
Fast data array index out of range. |
Index specified for fast data must be within the range. Refer to fast data properties in Reference Manual. |
SYNC |
Error |
Idle Task |
5026 |
Incorrect fast data check sum. |
Fast data are not initialized. The host must write valid data before the softMC reads it. |
SYNC |
Error |
Idle Task |
5027 |
Internal error. Contact technical support |
Internal error. Contact technical support. |
SYNC/ ASYNC |
Fatal Fault |
Watchdog |
5028 |
Device is blocked for safety reasons. |
N/A for MC |
N/A |
N/A |
|
5029 |
No such device. |
N/A for MC |
N/A |
N/A |
|
5030 |
Unknown error |
Internal error. Contact technical support |
Terminal |
Fatal Fault |
Watchdog |
5031 |
Internal error. Contact technical support. |
Could not create TCP socket |
SYNC |
Error |
Idle Task |
5032 |
Could not Bind IP address to TCP socket |
Could not Bind IP address to TCP socket |
SYNC |
Error |
Idle Task |
5033 |
Could not use TCP socket |
Could not “listen” to TCP socket |
SYNC |
Error |
Idle Task |
5034 |
Could not accept connection from host |
TCP “accept” failed |
SYNC |
Error |
Idle Task |
5035 |
Connection lost |
Connection lost |
SYNC |
Note |
None |
5036 |
Incorrect parameter value |
Incorrect parameter value |
SYNC |
Error |
Idle Task |
5037 |
Incorrect baud rate value |
Incorrect baud rate value |
SYNC |
Error |
Idle Task |
5038 |
Cannot configure port - incorrect settings |
Cannot configure port - incorrect settings |
SYNC |
Error |
Idle Task |
5039 |
Cannot configure port - incorrect settings |
Cannot configure port - incorrect settings |
SYNC |
Error |
Idle Task |
5040 |
Device handle is already use |
Device handle is already use |
SYNC |
Error |
Idle Task |
5041 |
Device handle is not valid - use OPEN command |
Device handle is not valid - use OPEN command |
SYNC |
Error |
Idle Task |
5042 |
Device handle is not valid - use OPEN command |
Device handle is not valid - use OPEN command |
SYNC |
Error |
Idle Task |
5043 |
Port or file is already open |
Port or file is already open |
SYNC |
Error |
Idle Task |
5044 |
Could not connect to server |
Could not connect to server |
SYNC |
Error |
Idle Task |
5045 |
Internal error. Contact technical support |
Out of memory. |
SYNC |
ERR_FAULT_FATAL |
Watchdog |
5046 |
Cannot execute a command while the Translator is busy |
Translator is still busy with previous command |
SYNC |
Error |
Idle Task |
5047 |
Cannot execute a command while the MODBUS is started |
Cannot execute a command while the MODBUS is started |
SYNC |
Error |
Idle Task |
5048 |
Translation of command in Entry station took too long |
Translation of command takes too much time.Typically happens at load of large library from the terminal. |
Sync |
Error |
|
5049 |
Execution of command in Entry station took too long. |
Interpretation of command takes too much time.Typically happens if function/procedure from global library called from terminal has endless loop. Use USER_SET_ES_LOCK_DETECT_TIMEOUT(timeout,0,0) user function to change the default timeout (3000 ms) |
Sync |
Error |
|
5050 |
Disk full. |
Disk full. |
SYNC |
Error |
Idle Task |
5052 |
Other connections are still active. |
"Reset all" fails because other computers/devices are connected to another Entry Station. |
SYNC |
Error |
|
Number |
Message |
Description |
Type |
Severity |
Action |
6001 |
Task already exists. |
When loading a user task or defining a new event, a process with the same name may already exist. Source : Load, OnEvent |
SYNC |
Error |
|
6002 |
Failed to open program file |
Failed to open a program file for reading because it: 1) does not exist, 2) there are too many open files, or 3) there is not enough memory. If error occurs on power up, verify the CONFIG.PRG file exists with valid data. |
SYNC |
Error |
|
6003 |
Bad element index. |
Internal error. Bad task index passed as a parameter. Indicates that system data are not reliable anymore. Data problem Source : Task priority updated, event prolog, epilog |
SYNC |
Fatal Fault |
|
6004 |
Array overflow |
Too many events/tasks defined (task load, event create) Source : Load, OnEvent |
SYNC |
Error |
|
6005 |
Failed to open translator map file. |
Internal error. Failed to create MAP file. Source: Loader |
SYNC |
Error |
|
6006 |
Cannot open translator error file. |
Internal error. Failed to create translator error file in root Source : Loader |
SYNC |
Error |
|
6007 |
Task must be killed first |
Cannot unload a task if it is not in either the killed or ready state. |
SYNC |
Error |
|
6008 |
Task does not exist |
When unloading the user task or event, the process with the specified name does not exist. Source: Unload, EventDelete, Task priority get. |
SYNC |
Error |
|
6009 |
Failed to run interpreter. |
Internal error. Failed to call interpreter function or spawn interpreter task. Resource problem Source : configuration (root),Load, OnEvent |
SYNC/ ROOT |
Error |
|
6010 |
Event task already exists |
Event task with given name already exists. |
SYNC |
Error |
|
6011 |
Failed to create data segment. |
Internal error. Cannot allocate data segment when Loading the task. Resource problem Source : Load |
SYNC |
Error |
|
6012 |
Failed to create code segment. |
Internal error. Cannot allocate code segment when loading the task. Resource problem Source : Load |
SYNC |
Error |
|
6013 |
Invalid semaphore ID. |
Internal error. Failed to take ITCB mutex. Bad pointer Source : any ITCB routine which tries to update ITCB data (Load, Unload, Priority etc, OnEvent etc.) |
SYNC |
Fatal Fault |
|
6014 |
Failed to create data stack. |
Internal error. Cannot create interpreter data stack when Load or OnEvent is attempted Resource problem Source : Load, OnEvent |
SYNC |
Error |
|
6015 |
Failed to create function stack. |
Internal error. Cannot create interpreter function stack when Load or OnEvent. Resource problem Source : Load, OnEvent |
SYNC |
Error |
|
6016 |
Failed to create command line code segment. |
Internal error. Cannot create command line code segment |
ROOT |
Fatal Fault |
|
6017 |
Failed allocate memory for event node. |
Internal error. Cannot allocate memory for event node. Resource problem Source : Load, prolog, epilog |
SYNC |
Error |
|
6018 |
Specified priority does not exist. |
Internal error. Lookup in event list by priority or by event itcb idx failed. The problem may lie with data reliability because some procedures look for elements in the event list. If the element is not in the list, the task is aborted Source: event list management, priority modify. Comment: cannot happen during normal runtime. |
SYNC/ ASYNC |
Fatal Fault |
|
6019 |
Invalid event node. |
Internal error. Invalid event ID. NULL reference to current/previous active events. Resource problem. Source: event management, priority modify. |
SYNC/ ASYNC |
Fatal Fault |
|
6020 |
Invalid parent task node. |
Internal error. Invalid parent task ID. Requested ITCB idx is not the same as in the event list. Data integrity violated. Source: Load, Unload Comment: cannot happen during normal runtime. |
SYNC |
Fatal Fault |
|
6021 |
Invalid interpreter pointer. |
Internal error. NULL pointer to internal interpreter registers encountered. Source : event management Comment: cannot happen during normal runtime. If the error occurs, then this task cannot be handled: NULL pointer to interpreter but ITCB index still exists. |
SYNC/ ASYNC |
Fatal Fault |
|
6022 |
Invalid operation code |
Internal error. Invalid operation code for loader handler |
SYNC |
Error |
|
6023 |
Invalid event list mutex. |
Cannot take event list mutex - it is invalid). Bad pointer Source : event management (prolog, epilog), Load, Unload, OnEvent |
SYNC/ ASYNC |
Fatal Fault |
|
6024 |
Failed to delete OnError handler |
Internal error. Cannot delete OnError handler (message queue, interpreter) Source: OnError. |
SYNC |
Error |
|
6025 |
Invalid OnError message queue |
Internal error. Invalid OnError message queue ID. Bad pointer. Source: sending error message to OnError task. |
ASYNC |
Fatal Fault |
|
6026 |
Reserved task priority |
Illegal priority 0 (which is reserved for OnError) specified Source : load, OnEvent, priority modify. |
SYNC |
Error |
|
6027 |
Invalid parent task semaphore |
Internal error. Happens when an attempt to take parent task sync semaphore fails. Source: Loader, OnEvent, OnError. |
SYNC |
Fatal Fault |
|
6028 |
Invalid translator mutex |
Internal error. Happens when an attempt to take translator mutex fails. Source : Loader, OnEvent, OnError |
SYNC |
Fatal Fault |
|
6029 |
Zero file size detected. |
Cannot load an empty file. |
SYNC |
Error |
|
6030 |
Failed to create user task error handler |
Internal error. Cannot create default task error handler (task spawn, message queue). Source : Load |
ROOT |
Fatal Fault |
|
6031 |
Command given in invalid context. |
Command given in invalid context. |
SYNC |
Note |
|
6032 |
Invalid priority range. |
Invalid priority specified. |
SYNC |
Note |
|
6033 |
Failed to create translator mutex |
Internal error. Occurs at start up when creating translator mutex fails. Source : Loader, OnEvent, OnError |
ROOT |
Fatal Fault |
|
6034 |
Failed to open translator output file. |
Internal error. Failed to create permanent translator output file. Source : Root |
ROOT |
Error |
|
6035 |
Failed to open backend output file. |
Internal error. Failed to create permanent backend output. Source : Root |
ROOT |
Fatal Fault |
|
6036 |
Cannot open translator string file. |
Internal error. Failed to create translator string file in root. Source : Root |
ROOT |
Fatal Fault |
|
6037 |
Failed to create mutex. |
Internal error. Failed to create loader mutex in ITCB initialization. Source : Root |
ROOT |
Fatal Fault |
|
6038 |
Failed to create sync semaphore |
Internal error. Root: there is one common sync semaphore for creating tasks and events. |
ROOT |
Fatal Fault |
|
6039 |
Failed to retrieve system settings |
Internal error. Failed to retrieve system settings. |
SYNC/ ASYNC |
Fatal Fault |
|
6040 |
Failed to create command line files. |
Internal error. Failed to create temporal command line files (ITCB init). Source : Root |
ROOT |
Fatal Fault |
|
6041 |
Cannot create tasks STDIN. |
Internal error. Failed to create temporal files. |
ASYNC |
Error |
|
6042 |
Cannot open tasks STDIN. |
Internal error. Failed to read from temporal task files. |
ASYNC |
Error |
|
6043 |
Cannot delete task STDIN |
Internal error. Failed to delete the input message queue for a task. |
SYNC |
Error |
|
6044 |
Cannot write to tasks STDIN. |
Internal error. Failed to write to temporal task files. |
ASYNC |
Error |
|
6045 |
Cannot Reset. Stop the task(s) first. |
RESET ALL is not allowed if a task is running. |
SYNC |
Error |
|
6046 |
File cannot be loaded |
This error occurs when trying to load config.prg, system, or other reserved file. |
SYNC |
Error |
|
6047 |
Invalid Translator mutex |
Internal error. Invalid mutex, Internal error due to memory corruption or limited memory. |
SYNC |
Fatal Fault |
|
6048 |
Invalid operation code |
Internal error. Invalid operation code. |
SYNC |
Fatal Fault |
|
6049 |
Cannot unload library. which is in use. |
Failed to unload the library since it is used by other tasks, unload the tasks first. |
SYNC |
Error |
|
6050 |
Unknown error |
Internal error: unknown error code. |
SYNC |
Fatal Fault |
|
Number |
Message |
Description |
Type |
Severity |
Action |
7001 |
Error writing to internal translator output file |
Error writing to output file of translator. The translator uses a temporary output file on the RAM disk. Add more memory or delete unneeded REC files. This error aborts the translation process. |
SYNC |
Fault |
|
7002 |
Error writing to internal translator temporary file |
Error writing to the temporary files of the translator. The translator uses a temporary file on the RAM disk. Add more memory or delete unneeded REC files. This error aborts the translation process. |
SYNC |
Error |
|
7003 |
Error writing to translator error file |
Error writing to the error file of the translator. The translator error file is stored on the RAM disk. Add more memory or delete unneeded REC files. This error aborts the translation process. |
SYNC |
Error |
|
7005 |
Errors found during translation |
Errors were found during translation. This general message is returned after a LOAD command if translation errors were found in the task. The error severity will be FATAL FAULT if a translation error is found in the CONFIG.PRG file. |
SYNC |
Error |
|
7006 |
Variable could not be added to internal symbol table |
Internal error. Add more memory. This error will abort the translation process. |
SYNC |
Error |
|
7007 |
Variable already declared |
A variable can be declared only once. |
Translation |
Error |
|
7008 |
Subroutine already exists |
The subroutine has already been defined |
Translation |
Error |
|
7009 |
Translator temp file could not be opened |
Internal error. The temporary file of the translator could not be opened. |
SYNC |
Error |
|
7010 |
Value out of range |
Value out of range. |
SYNC |
Error |
|
7013 |
Undefined motion element in command |
The motion element (axis or group) you are trying to use is undefined |
Translation |
Error |
|
7014 |
Group cannot be added to symbol table |
The symbol table is an internal data structure. If information cannot be written to it, there is not enough memory. Add more memory. |
SYNC |
Error |
|
7015 |
Group is already defined |
The group being declared already exists. Use a different name for the group. |
Translation |
Error |
|
7016 |
Too many axes in Group definition |
There are too many axes in the group definition |
SYNC |
Error |
|
7017 |
Group cannot be deleted: unload all tasks first |
The group cannot be deleted if tasks are loaded in memory. |
Terminal |
Error |
|
7018 |
Internal translation error |
Internal error |
SYNC |
Error |
|
7019 |
Variable does not exist |
The variable you're trying to use does not exist. Make sure it has been declared. |
Translation |
Error |
|
7020 |
No default motion element: use the WITH instruction |
You are trying to use a command without explicitly defining a motion element, and a default motion element has not been defined by the WITH instruction. |
Translation |
Error |
|
7021 |
Property valid for Axis only |
This property is valid only for axes |
Translation |
Error |
|
7022 |
Could not change axis name |
Internal error. Contact technical support. |
Translation |
Error |
|
7023 |
Axis could not be created |
Internal error. Contact technical support. |
ROOT |
Error |
|
7024 |
Axes not created |
Axes not created. |
ROOT |
Error |
|
7025 |
Too many values into vector |
Too many values into vector |
SYNC |
Error |
|
7026 |
Too many variable names: simplify the expression |
The maximum number of variables allowed in an expression is 20. |
Translation |
Error |
|
7027 |
Instruction given in invalid context |
The command you are trying to use cannot be used in this context. Check the allowed scope of the instruction in the Reference Manual. |
Translation |
Error |
|
7028 |
PROGRAM must be on the first line |
The PROGRAM keyword must be on the first line |
SYNC |
Error |
|
7029 |
Program symbol table not created |
Internal error. An internal data structure could not be created. Add more memory or delete unneeded files. |
SYNC |
Error |
|
7032 |
CALL references non-existent SUB |
You are trying to call a subroutine that does not exist. The subroutine must be defined. |
Translation |
Error |
|
7034 |
Translator Initialization failure |
Internal error. The translator could not be initialized. Contact technical support. |
ROOT |
Fatal Fault |
|
7035 |
Translator syntax error |
The syntax of the expression is wrong. Check correct syntax in Reference manual. |
Translation |
Error |
|
7036 |
Program structure error |
The program must adhere to a well-defined structure. Refer to the section on tasks in the User's Manual. |
Translation |
Error |
|
7037 |
Not enough space for parser stacks |
Not enough space for parser stacks |
SYNC |
Error |
|
7038 |
Parser stack overflow |
Parser stack overflow |
SYNC |
Error |
|
7039 |
Syntax Error |
Syntax Error |
SYNC |
Error |
|
7040 |
Translator out of memory |
Translator out of memory |
SYNC |
Error |
|
7041 |
Invalid numbers of drives |
Invalid numbers of drives ( SERCOS ) |
SYNC |
Error |
|
7042 |
Event definition not allowed in event action |
Event definition is not allowed in event action |
SYNC |
Error |
|
7043 |
Event already defined in this program |
Event already defined in this program |
SYNC |
Error |
|
7044 |
Could not create new event symbol. |
Could not create new event symbol. Internal error |
SYNC |
Error |
|
7045 |
Unmatched end of event definition block |
Unmatched end of event definition block |
SYNC |
Error |
|
7046 |
Parameter repetition not allowed |
Parameter repetition not allowed |
SYNC |
Error |
|
7047 |
Undefined event |
Undefined event |
SYNC |
Error |
|
7048 |
Label repeated in the same block |
Label repeated in the same block |
SYNC |
Error |
|
7049 |
GOTO references non-exisiting label |
GOTO references non-exisiting label |
SYNC |
Error |
|
7050 |
String too long ( limit = 80 char) |
String too long ( 80 characters ) |
SYNC |
Error |
|
7051 |
Too many dimension in declaration - maximum is 10. |
Too many dimension in a declaration (maximum number of dimensions is 10) |
SYNC |
Error |
|
7052 |
Number of dimension does not match declaration |
Number of dimension does not match declaration |
SYNC |
Error |
|
7053 |
Label repeated in the same block |
Label repeated in the same block |
SYNC |
Error |
|
7054 |
If block mismatch |
An If block must end with an End If statement |
SYNC |
Error |
|
7055 |
While block mismatch |
A While block must end with an End While statement. |
SYNC |
Error |
|
7056 |
For block mismatch |
AFor block must end with a Next {variable_name} statement. |
SYNC |
Error |
|
7057 |
Invalid array index |
Invalid array index |
SYNC |
Error |
|
7058 |
Name already declared as variable, axis, group, or function |
Name already declared as variable, axis, group, or function |
SYNC |
Error |
|
7059 |
Invalid number of coordinates |
This error occurs when performing an operation between two points with mismatching number of coordinates. |
SYNC |
Error |
|
7060 |
Name of group is invalid |
Name of group is invalid |
SYNC |
Error |
|
7061 |
Variable cannot be deleted from the symbol table |
Variable cannot be deleted from the symbol table |
SYNC |
Error |
|
7063 |
Error definition allowed only once in program |
Error definition allowed only once in program |
SYNC |
Error |
|
7064 |
Unmatched end of error definition block |
Unmatched end of error definition block |
SYNC |
Error |
|
7065 |
Command not allowed into OnError block |
Command not allowed into OnError block |
SYNC |
Error |
|
7066 |
Wrong index type. Index must be of long type |
The type of the index of the array must be long |
SYNC |
Error |
|
7067 |
Wrong input type |
Wrong input type. |
SYNC |
Error |
|
7068 |
Index of array must be a constant value |
The number of elements in an array must be declared with a constant value. |
SYNC |
Error |
|
7069 |
Name is a reserved command name or contains invalid symbols |
Variables, system elements, subroutines and functions cannot have a name identical to a reserved command name, or a name containing symbols other than letters, numbers and underlines. |
SYNC |
Error |
|
7071 |
With block mismatch |
A With block definition must end with the End With statement |
SYNC |
Error |
|
7072 |
Case Select block mismatch |
A Select Case block must end with an End Select statement. |
SYNC |
Error |
|
7073 |
Invalid name of motion element |
Invalid name of motion element |
SYNC |
Error |
|
7074 |
Property valid for group only |
Property valid for group only |
SYNC |
Error |
|
7075 |
Too many spaces |
Too many consecutive spaces (more than 83) in a command |
SYNC |
Error |
|
7076 |
Motion element must be an axis |
Motion element must be an axis |
SYNC |
Error |
|
7077 |
Motion element must be a group |
Motion element must be a group |
SYNC |
Error |
|
7078 |
This property isn't a system property |
This property isn't a system property |
SYNC |
Error |
|
7079 |
Wrong given master type |
Incorrect master type (3 master types currently defined) |
SYNC |
Error |
|
7084 |
Wrong syntax for joints |
Command cannot be applied for joint axes (J axes). |
|
|
|
7087 |
Dimension mismatch |
Dimension mismatch. Used when trying to assign an array during declaration. |
|
Error |
|
7089 |
User function does not exist |
A user function is called that does not exist or is not loaded into memory |
SYNC |
Error |
|
7090 |
System camming element does not exist |
System camming element does not exist |
|
Error |
|
7091 |
Camming element can only be a system element |
Camming element can only be a system element (not a program or a local variable ) |
|
Error |
|
7092 |
Wrong input type for the select statement. |
Invalid input type. |
|
Error |
|
7095 |
The hex/decimal/bin keywords can only be used in a query command |
The hex/decimal/bin keywords can only be used in a query command |
SYNC |
Error |
|
7096 |
OnError can be defined only once in a program |
OnError can be defined only once in a program |
SYNC |
Error |
|
7097 |
Incorrect print format |
This error occurs if the print format for a print using statement is incorrect. |
SYNC |
Error |
|
7100 |
This property is a nodal only property |
This property is a nodal only property |
SYNC |
Error |
|
7102 |
Try block mismatch |
A Try block must end with an End Try statement. |
SYNC |
Error |
|
7103 |
Cannot write a catch-case after the finally-case |
A user cannot write another catch statement after the finally statement. |
SYNC |
Error |
|
7104 |
This is a read-only property |
Cannot assign a property that is read only. |
SYNC |
Error |
|
7105 |
Undefined PLS in command |
Undefined PLS in command |
SYNC |
Error |
|
7106 |
PLS could not be added to symbol table |
A PLS could not be added to the symbol table. This is due to a memory fault. |
SYNC |
Error |
|
7107 |
PLS is already defined |
PLS is already defined. |
SYNC |
Error |
|
7108 |
Invalid PLS name |
Name of PLS is invalid. |
SYNC |
Error |
|
7109 |
The with block must be closed before entering this block |
The with block must be closed. |
SYNC |
Error |
|
7110 |
Cannot use locals in this context |
Must use a global and program variables in the event conditions and inside event blocks. |
SYNC |
Error |
|
7111 |
The maximal length of the expression must be less than 128 |
The maximum length of the expression must be less than 128 characters. |
SYNC |
Error |
|
7113 |
Expression can only contain strings |
Expression can only contain strings |
SYNC |
Error |
|
7114 |
This function cannot be used as a condition |
This function cannot be used as a event condition. |
SYNC |
Error |
|
7115 |
The PLS cannot be declared into a program |
The PLS cannot be declared in a program context. |
SYNC |
Error |
|
7117 |
Missing end onevent statement |
Missing end onevent statement |
SYNC |
Error |
|
7118 |
Then statement missing |
A THEN statement is missing in the IF statement |
SYNC |
Error |
|
7119 |
Library function is not loaded into memory |
Did not load the Library file that contains this function/subroutine. |
SYNC |
Error |
|
7120 |
Cannot record this kind of expression |
Cannot record this kind of expression. |
SYNC |
Error |
|
7121 |
This is not a subroutine, but this is a function |
Tried to use subroutine syntax for a function. |
SYNC |
Error |
|
7122 |
This is not a function, but this is a subroutine |
Tried to use function syntax for a subroutine. |
SYNC |
Error |
|
7123 |
Multiple definition of Else statement |
More then one Else statement in a single If block. |
SYNC |
Error |
|
7124 |
Multiple definitions of Next statement |
More then one Next statement in a single For block. |
SYNC |
Error |
|
7125 |
Cannot record a vector |
Cannot record a vector (point). |
SYNC |
Error |
|
7126 |
Cannot use vector for condition |
Cannot use a vector (point) as condition in event definition, flow control statements, etc. |
SYNC |
Error |
|
7127 |
The record file or number of recording points is missing |
The record file or number of recording points is missing. |
SYNC |
Error |
|
7128 |
The recorder file is missing |
The recorder file is missing. |
SYNC |
Error |
|
7129 |
Cannot use this operator for strings |
This operator is not valid for strings. For example, you cannot multiply strings. |
SYNC |
Error |
|
7130 |
Cannot import library file. Library file must be loaded into memory |
Library file must be loaded into memory before importing it. |
SYNC |
Error |
|
7131 |
Cannot import file which isn’t a library file |
The import command is valid only for Library files. |
SYNC |
Error |
|
7132 |
Input can only contain one string input |
Tried to use an input that is not a string in Prompt command. |
SYNC |
Error |
|
7133 |
Catch statement is missing or must be before the statement block |
Catch statement is missing or must be before the statement block. |
SYNC |
Error |
|
7134 |
A filename cannot have more than 8 characters |
A filename cannot have more than 8 characters. |
SYNC |
Error |
|
7135 |
Wrong input parameter for the Print command |
The print command has wrong input parameter. |
SYNC |
Error |
|
7136 |
Declaration type is missing |
The variable type is missing from the variable declaration statement. |
SYNC |
Error |
|
7137 |
Parameter name is a reserved command name or contains invalid symbols |
A parameter cannot have a name identical to a reserved command name, or a name containing symbols other than letters, numbers and underlines. |
SYNC |
Error |
|
7138 |
Cannot use wildcards for this command |
Can not use wildcards (*, ?) for this command. |
SYNC |
Error |
|
7139 |
Variable passed by reference has another type as in subroutine/function declaration |
The variable’s type does not match the type of the corresponding subroutine/function parameter. |
SYNC |
Error |
|
7140 |
Cannot pass a constant or a complex expression by reference to subroutine/function |
Cannot pass a constant or a complex expression (for example: Var1+Var2) by reference to subroutine or function. |
SYNC |
Error |
|
7141 |
Cannot use external device for this command |
Cannot use an external device (dump terminal) for this command. |
SYNC |
Error |
|
7142 |
Use only long type constants for array size definition |
Only long type decimal numbers and constants can be used for array size definition (in an array declaration statement) |
SYNC |
Error |
|
7143 |
Cannot import a global library |
Cannot apply the Import command on a global library. |
SYNC |
Error |
|
7144 |
Subroutine already exists in a global library |
Name of subroutine or function was already given to a global subroutine of function |
SYNC |
Error |
|
7145 |
The Nodal parameter is inappropriate for this type of motion command |
The Nodal parameter cannot be used in this type of motion command (for example: VelocityFinalTrans cannot be used in Move command) |
SYNC |
Error |
|
7146 |
Expression can only contain points |
Expression can only contain points (for example: assignment of point-type group properties) |
SYNC |
Error |
|
7147 |
Wrong robot-type |
An invalid robot type was given during declaration or Save command |
SYNC |
Error |
|
7148 |
Robot-type mismatch |
Robot-type mismatch between point variables or point parameters |
SYNC |
Error |
|
7149 |
Statement cannot contain points |
Statement cannot contain points (for example: a Select Case statement) |
SYNC |
Error |
|
7150 |
Too many coordinates in a vector |
A vector cannot contain more than 10 coordinates. |
SYNC |
Error |
|
7151 |
Cannot use this operator for points |
Cannot use this operator for points (for example: logic operators) |
SYNC |
Error |
|
7152 |
Cannot use vectorial multiplication for points |
Cannot multiply or divide a point by a point. |
SYNC |
Error |
|
7153 |
The variable parameter must be an array |
Parameter of command or system function is an array. |
SYNC |
Error |
|
7154 |
Incorrect pls type |
Incorrect pls type |
SYNC |
Error |
|
7155 |
Cannot access a member of a returned-value structure through function call |
Cannot access a member of a returned-value structure through function call. For example: ? StructFunc(…, …)->member1 |
SYNC |
Error |
|
7156 |
Too many structure members |
Too many structure members |
SYNC |
Error |
|
7157 |
Name already given to another member of this structure-type |
Name was already given to another member of the same structure type. |
SYNC |
Error |
|
7158 |
Wrong type for a structure member |
Wrong type for a structure member (for example: nesting of structures). |
SYNC |
Error |
|
7159 |
Name already declared as a structure-type |
Name of structure type was already given to another structure type. |
SYNC |
Error |
|
7160 |
Undefined structure-type |
Unknown structure type or variable type in variable declaration command. |
SYNC |
Error |
|
7161 |
Structure-type mismatch |
Structure-type mismatch between structures. |
SYNC |
Error |
|
7162 |
Cannot use this operator for structures |
Cannot use this operator for structures (for example: all arithmetic operators). |
SYNC |
Error |
|
7163 |
Expression can only contain structures |
In assignment statement, the expression being assigned into a structure must be a structure too. |
SYNC |
Error |
|
7164 |
Statement cannot contain structures |
Statement cannot contain structures (for example: a For loop index). |
SYNC |
Error |
|
7165 |
Cannot pass a structure member by reference to a subroutine/function |
Cannot pass a structure member by reference to a subroutine/function |
SYNC |
Error |
|
7166 |
Undefined structure member |
The structure member was not defined in the structure type. |
SYNC |
Error |
|
7167 |
A semaphore can only be a system element |
A semaphore cannot have local or program scope. |
SYNC |
Error |
|
7168 |
Cannot pass an array by value to subroutine/function |
Cannot pass an array by value to subroutine/function |
SYNC |
Error |
|
7169 |
Use only long type decimal values as error numbers in catch statements |
Only long-type numbers can be used as error numbers in catch statements. |
SYNC |
Error |
|
7170 |
A moving frame can only be a system element |
A moving frame cannot have local or program scope. |
SYNC |
Error |
|
7171 |
Moving frame element does not exist |
Moving frame element does not exist. |
SYNC |
Error |
|
7172 |
A compensation table can only be a system element |
A compensation table cannot have local or program scope. |
SYNC |
Error |
|
7173 |
Compensation table does not exist |
Compensation table does not exist |
SYNC |
Error |
|
7175 |
This function has no return value |
Cannot call a C function that does not return a value through expression statements (for example: by query). |
SYNC |
Error |
|
7176 |
This function must be used as an expression |
C function returns a value and therefore must be called through expression statements (for example: by query). |
SYNC |
Error |
|
7178 |
Cannot pass an axis or a group by value to subroutine/function |
Cannot pass an axis or a group (“real” or generic) by value to subroutine/function |
SYNC |
Error |
|
7180 |
Cannot use this command or operation for generic axes and groups |
Cannot use this command or operation for generic axes and groups (for example: using generic axes for declaration of a real group) |
SYNC |
Error |
|
Number |
Message |
Description |
Type |
Severity |
Action |
8001 |
Division by zero |
Division by zero. |
SYNC |
Error |
Idle Task |
8002 |
Internal error. Contact technical support. |
Interpreter stack underflow. The possible cause is memory corruption or Translator generated invalid code. |
SYNC |
Fault |
Interpreter is prevented from execution. |
8003 |
Stack overflow. |
Memory exhausted. |
SYNC |
Fault |
Interpreter is prevented from execution. |
8004 |
Internal error. Contact technical support. |
Interpreter stack underflow. The possible cause is memory corruption or Translator generated invalid code. |
SYNC |
Fault |
Interpreter is prevented from execution. |
8005 |
Functions stack overflow. |
Memory exhausted. |
SYNC |
Fault |
Interpreter is prevented from execution. |
8006 |
Index underflow. |
Invalid array index value. |
SYNC |
Fault |
|
8007 |
Index overflow. |
Invalid array index value. |
SYNC |
Fault |
|
8008 |
Task not found. |
Task operation failed. Requested task does not exist. |
SYNC |
Error |
|
8009 |
Invalid breakpoint location. |
Attempt to set breakpoint to invalid location. Example: on comment line or on existing breakpoint. |
SYNC |
Error |
|
8010 |
Out of memory. |
Memory exhausted. Add more memory or unload unnecessary tasks. |
SYNC |
Fatal |
|
8011 |
Internal error. Contact technical support |
Run time error in the external to interpreter function. |
SYNC |
Error |
|
8012 |
The task has not terminated. |
The task execution has not been terminated. This may occur if task is locked within some end-function, such as MOVE or STOP. |
SYNC |
Error |
|
8013 |
The task is not stopped. |
The task is not stopped (idled). |
SYNC |
Error |
|
8014 |
The task is terminated. |
Task is terminated (killed). |
SYNC |
Error |
|
8015 |
Argument for EXP is out of range |
The range of values for the EXP argument is ± 7.09782712893383e+02. Values less than the lower limit can be used, but will return 0. |
SYNC |
Error |
|
8016 |
llegal mathematical function call |
Invalid argument for mathematical function. |
SYNC |
Error |
|
8017 |
Argument for LOG is out of range |
The argument to the LOG function must be greater than zero. |
SYNC |
Error |
|
8018 |
Negative parameter in SQRT operator |
The argument to the SQRT function must be greater than or equal to zero. |
SYNC |
Error |
|
8019 |
Internal error. Contact technical support. |
Loader passes invalid context definition. |
SYNC |
Fatal Fault |
|
8020 |
Varible does not exist. |
Variable for watch does not exist. |
SYNC |
Error |
|
8021 |
Incorrect number of dimensions. |
Wrong number of dimentions for watch. |
SYNC |
Fault |
|
8022 |
Task is not running. |
Task is stopped (idled). |
SYNC |
Error |
|
8023 |
Internal error. Contact technical support. |
Element could not be deleted from symbol table. |
SYNC |
Fault |
|
8024 |
Task must be killed first. |
Task is still running. It may be locked in some end-function such as MOVE. |
SYNC |
Error |
|
8025 |
Invalid task state for the `StartTask` command. Kill task first. |
Task is not terminated (killed). It may be locked in some end-function such as MOVE. |
SYNC |
Error |
|
8026 |
Bad memory address. |
Attempted access to an invalid memory address. The error may be due to either a mistake in the application or to memory corruption. |
SYNC |
Error |
|
8027 |
Bad I/O address. |
Attempted access to an invalid I/O address. The error may be due to either a mistake in the application or to memory corruption. |
SYNC |
Error |
|
8028 |
Calculation overflow |
Overflow in calculations. |
SYNC |
Error |
|
8029 |
Underflow |
Underflow in calculations. |
SYNC |
Error |
|
8030 |
Internal error. Contact technical support |
Invalid mutex ID. The error may be due to memory corruption. |
SYNC |
Fatal Fault |
|
8031 |
Internal error. Contact technical support |
Invalid mutex ID. The error may be due to memory corruption. |
SYNC |
Fatal Fault |
|
8032 |
Internal error. Contact technical support |
Error while creating the semaphore. The error occurs when memory is exhausted. |
SYNC |
Fatal Fault |
|
8033 |
Internal error. Contact technical support |
Code segment has invalid check sum. The reason is memory corruption. |
SYNC |
Fatal Fault |
|
8034 |
Internal error. Contact technical support |
Invalid token COP; usually due to memory corruption. |
SYNC |
Fatal Fault |
|
8035 |
Task is interrupted by OnEvent or OnError |
A task debugging command such as STEP or STEPOVER, etc. is disabled due to an interrupted state of a task. The task switches to this state if it is interrupted by ONERROR or ONEVENT. |
SYNC |
Error |
|
8036 |
Entry Station output buffer overflow |
Entry Station output buffer overflow. Error is caused by an inoperable host or user task sends too many messages. |
SYNC |
Note |
|
8037 |
Error loading object file (see file oload.err for more details). |
Object file is not valid or contains unresolved symbols |
SYNC |
Note |
|
8038 |
The value is out of range |
The value passed to the function is out of range |
SYNC |
Error |
|
8039 |
Invalid file name |
Invalid file name |
SYNC |
Error |
|
8040 |
Invalid time or date |
Invalid time or date entered. |
SYNC |
Error |
|
8041 |
Nothing to retry. |
Retry command is applicable anly after a run-time error. |
SYNC |
Error |
|
8042 |
Task is busy. |
Task is busy; debugging is not allowed. This happens when task is inside the end function. |
SYNC |
Error |
|
8043 |
Element could not be deleted while programs are in memory. |
Element could not be deleted while programs are in memory. |
SYNC |
Fault |
|
8045 |
Cannot stop unbreakable task. |
Cannot stop or debug unbreakable task |
SYNC |
Error |
|
8046 |
"User authorization code is not recognized. Contact technical support |
Contact technical support to validate both Serial Number of your card and Authorisation code |
SYNC |
Error |
No axes available |
8047 |
Invalid Authorization code! Contact technical support |
Contact technical support to validate your Authorisation code. |
SYNC |
Error |
No axes available |
8049 |
Invalid type of variable |
Wrong type of variable |
SYNC |
Error |
|
8050 |
Argument for trigonometric function is out of range |
The maximum value of the argument to a sin(x) or cos(x) is 9.223372036854699e+18 |
SYNC |
Error |
|
8051 |
The result of mathematical function overflows |
The magnitude of the result is greater than the maximum value of the Double type. |
SYNC |
Error |
|
8052 |
Internal error. Contact technical support |
Element could not be added to symbol table. Internal Error |
SYNC |
Fault |
|
8053 |
No permission: stop the motion first |
Motion should be stopped before RESET. |
SYNC |
Fault |
|
8054 |
Unrecognized Serial Number. Contact technical support |
Contact technical support to validate both Serial Number of your card and Authorisation code |
SYNC |
Error |
No axes available |
8055 |
Event/OnError cannot kill a task in which defined. |
Event/OnError cannot kill a task in which defined. |
SYNC |
Error |
|
8056 |
Wrong file type for this operation |
Wrong file type for this operation |
SYNC |
Error |
|
8057 |
Invalid time |
Invalid time |
SYNC |
Error |
|
8058 |
Invalid date |
Invalid date |
SYNC |
Error |
|
8059 |
Cannot unload a global library while tasks are in memory |
Cannot unload a global library while tasks are in memory |
SYNC |
Error |
|
8060 |
Global subroutine, function or library could not be deleted from symbol table. |
Global subroutine, function or library could not be deleted from symbol table. |
SYNC |
Error |
|
8061 |
Subroutine/function contains a call to a non-existent global subroutine/function. |
Subroutine/function contains a call to a non-existent global subroutine/function. |
SYNC |
Error |
|
8062 |
The file name is too long. A file name should contain no more than 8 characters. |
The file name is too long. A file name should contain no more than 8 characters. |
SYNC |
Error |
|
8063 |
Error in OnSystemError task |
|
SYNC |
Error |
|
Number |
Message |
Description |
Type |
Severity |
Action |
12001 |
Service Channel not open |
Drive indicates it cannot open the service channel. Contact technical support. |
SYNC |
Error |
|
12002 |
MDT telegram processing overrun |
Overlap between reference generation and transmission. Try using a higher baud rate, longer cycle time, and reducing the amount of cyclic data. |
ASYNC |
Error |
|
12003 |
Interrupt Service Routine Overlap: use longer cycle time. |
ISR's duration is too long (more than one communication cycle). Try using a higher baud rate, longer cycle time, and reducing the amount of cyclic data. |
SYNC |
Error |
|
12004 |
Service channel timeout waiting for drive |
Timeout during service channel transmission. Change the communication phase to 0 and try using longer cycle time. If error persists, call technical support. |
SYNC |
Error |
|
12005 |
Service channel timeout while drive is busy |
Timeout during service channel transmission. Change the communication phase to 0, bring the ring up and try again. Another solution would be using longer cycle time. If error persists, call technical support |
SYNC |
Error |
|
12006 |
Undefined error number |
Undefined error code. Internal error. Contact technical support. |
SYNC |
Fatal Fault |
Watchdog |
12007 |
Axis cannot be enabled: check C1D and Remote Enable |
This error occurs if the softMC times out while trying to enable the drive. A drive cannot be enabled if the drive is reporting a C1D error or if the drive's hardware enable signal is Off. You can check this by querying IDN P15 in the CD drive. |
SYNC |
Error |
|
12008 |
Axis cannot be disabled |
This error occurs if the softMC times out while trying to disable the drive. Refer to IDN207 in the drive or contact technical support. |
SYNC |
Error |
Bring the ring down to CP0 |
12009 |
Invalid access to closing the Service Channel |
Internal error. Contact technical support. |
SYNC |
Error |
|
12010 |
Axis in group cannot be enabled: check C1D and Remote Enable |
This error occurs if the softMC times out while trying to enable the drive. A drive cannot be enabled if the drive is reporting a C1D error or if the drive's hardware enable signal is Off. You can check this by querying IDN P15 in the CD drive. |
SYNC |
Error |
|
12011 |
Axis in group cannot be disabled |
This error occurs if the softMC times out while trying to disable the drive. Refer to IDN207 in the drive or contact technical support. |
SYNC |
Error |
Bring the ring down to CP0 |
12012 |
Drive not ready for power up |
A drive cannot be enabled if the drive is reporting a C1D error or if the drive's hardware enable signal is Off. |
SYNC |
Error |
|
12013 |
Drive reports fault in C1D: read IDN 95 to get the error |
When a drive fault occurs, the drive decelerates to a stop and releases torque. The C1D status bit is set and the corresponding fault bits are set in IDN 11. Faults are reset using IDN 99. |
SYNC/ASYNC |
Error |
Drive is disabled |
12014 |
Telegram data corrupted |
Telegram data received from the drive is invalid. Contact technical support. |
ASYNC |
Note |
|
12015 |
One of the programming error flags is active |
One of the SERCOS programming times was incorrect. Contact technical support. |
ASYNC |
Error |
|
12016 |
Invalid drive address |
There may be a conflict between the axis DriveAddress and Simulated properties. If an axis is simulated, the drive address must be set to 0. If the axis is real, the simulated property must be set to 0 (Off). Check if exists on ring drive in this address. |
SYNC |
Error |
|
12017 |
No IDN: IDN being accessed is not defined in the drive |
The IDN number being used is not defined in the drive. Check the drive manual. |
SYNC |
Error |
|
12022 |
Bad handle-function index |
Internal error. Contact technical support. |
SYNC |
Error |
|
12023 |
Service channel data not initialized |
Internal error. Contact technical support |
SYNC |
Error |
|
12024 |
Wrong bus bus operation mode |
The command requires EtherCAT/CAN bus to be in OP state or phase #4 in case of SERCOS bus. |
SYNC |
Error |
|
12025 |
Invalid access to the element 1 |
Element 1 of the IDN holds the IDN number. Access to this element is read-only. |
SYNC |
Error |
|
12026 |
Wrong ring number |
Internal error. Contact technical support. |
SYNC |
Fatal Fault |
Watchdog |
12027 |
Too many drives for this ring. |
Internal error. Contact technical support. |
SYNC |
Error |
|
12028 |
Wrong AT number. |
Internal error. Contact technical support. |
SYNC |
Error |
|
12029 |
Not enough memory. |
Not enough memory to allocate internal data structures. Add memory or unload unnecessary tasks. |
SYNC |
Error |
|
12030 |
SERCOS ring is broken: check the SERCOS wiring |
At the transition from Phase 0 to Phase 1, the softMC checks whether the ring is closed by transmitting data and then verifying that it receives this data. This error occurs if the ring is open. In some cases, an invalid baud rate setting causes this error. |
SYNC |
Error |
|
12031 |
No memory to maintain Service container |
Try to use less drives on the ring or contact technical support. |
SYNC |
Error |
|
12032 |
Service transfer not ready |
Internal error. Contact technical support. |
SYNC |
Error |
|
12033 |
No name |
Element 2 of drive's IDN table should contain the name of the IDN. The IDN has not been assigned a name. |
SYNC |
Error |
|
12034 |
Name transmission too short |
Drive expects more information for the IDN name. |
SYNC |
Error |
|
12035 |
Name transmission too long. |
Drive expects less information for the IDN name. |
SYNC |
Error |
|
12036 |
Name cannot be changed |
The name of the IDN may not be changed. |
SYNC |
Error |
|
12037 |
Name is write-protected at this time. |
The name of the IDN cannot be changed in the current communication phase. |
SYNC |
Error |
|
12038 |
Service transfer data unavailable |
Internal error. Contact technical support. |
SYNC |
Error |
|
12039 |
Initialization error |
An error occurred during Initialization of the SERCOS module. |
ROOT |
Fatal Fault |
Watchdog |
12040 |
Service channel hand-shake time-out. |
Service channel hand-shake time-out. Drive does not acknowledge service transmission. |
SYNC |
Error |
|
12041 |
Missing telegram(s): communication interrupted |
Controller did not receive telegram from the drive(s) in communications phase 2. This error is generated when a drive stops functioning, or when there is a timing problem on the SERCOS bus. |
SYNC |
Error |
Bring the ring down to CP0 |
12042 |
DPRAM overflow. Two many drives for this ring |
Not enough DPRAM space to allocate data structures. Try configure less cyclic data in telegrams (IDN’s 16 and 24) or use less drives. |
SYNC |
Error |
|
12043 |
Data element too long |
This error occurs when drive cannot accept long data array for the particular IDN. |
SYNC |
Error |
|
12044 |
Error calculating T2: increase cycle time or baud rate |
Error calculating MDT starting time. There is an expected time overlap between the AT's and the MDT. Either increase the cycle time, increase baud rate, simplify the telegrams, or decrease the number of drives. |
SYNC |
Error |
|
12045 |
Error calculating T3 |
Error calculating command value valid time. The time calculated for T3 exceeds the SERCOS cycle time. This may be due to different drives being on the ring, with different processing requirements. |
SYNC |
Error |
|
12046 |
Error calculating T4 |
Error calculating feedback acquisition capture point. The time calculated for T4 exceeds the SERCOS cycle time. This may be due to different drives being on the ring, with different processing requirements. |
SYNC |
Error |
|
12047 |
Error calculating TEND |
Error calculating end of transmission time. The time calculated exceeds the SERCOS cycle time. Increase the cycle time, increase baud rate, simplify the telegrams, or decrease the number of drives. |
SYNC |
Error |
|
12048 |
No service data |
Internal error. Contact technical support. |
SYNC |
Error |
|
12050 |
Attribute transmission too short |
Internal error. Contact technical support. |
SYNC |
Error |
|
12051 |
Attribute transmission too long |
Internal error. Contact technical support. |
SYNC |
Error |
|
12052 |
Attribute cannot be changed |
Element 3 of the IDN is write protected. Attribute cannot be changed. |
SYNC |
Error |
|
12053 |
Attribute is write protected at this time |
Cannot change the attribute in the current communication phase. |
SYNC |
Error |
|
12054 |
Service transfer not error-free |
Internal error. Contact technical support |
SYNC |
Error |
|
12055 |
Missing telegram(s): communication interrupted |
Controller did not receive telegram from the drive(s). This error is generated if a drive stops functioning, or if there is a timing problem on the SERCOS bus. Communication interrupted due to missing telegram(s) in communication phase 3 or communication phase 4. |
ASYNC |
Error |
Bring the ring down to CP0 |
12056 |
Wrong IDN number: the IDN must be defined |
One of the IDN’s wasn’t defined or there are no free place for this IDN. If error persists, call technical support. |
SYNC |
Error |
|
12057 |
Wrong telegram type specified in IDN15 |
Data telegram type number is out of range (0..7). |
SYNC |
Error |
|
12058 |
Wrong element number: must be in range 1..7 |
An IDN has 7 elements, each storing a different attribute of the IDN. Element number 7 is used to store the value of the IDN, and it is the element most frequently used. The element range is 1 to 7. |
SYNC |
Error |
|
12059 |
Communication phase 3 transition check failed |
Execution of CP2 to CP3 transition procedure (IDN127) failed. Check IDN 21 to obtain a list of invalid operation data. |
SYNC |
Error |
|
12060 |
Communication phase 4 transition check failed |
Execution of CP3 to CP4 transition procedure IDN#00128 failed. Check IDN 22 to obtain a list of invalid operation data. |
SYNC |
Error |
|
12061 |
Error creating MutEx for the Service channel task |
Internal error. Contact technical support |
SYNC |
Fatal Fault |
Watchdog |
12062 |
Cannot create MsgQ to provide service transmission |
Internal error. Contact technical support |
SYNC |
Fatal Fault |
Watchdog |
12063 |
Error creating Service event semaphore |
Internal error. Contact technical support. |
SYNC |
Fatal Fault |
Watchdog |
12064 |
Cannot pass communication phase 1: drive address(es) not declared. |
Drive addresses must be declared explicitly (<axis>.DRIVEADDRESS) or implicitly (SERCOS.SCAN) for the ring to be scanned. The SERCOS.SCAN property can be used for automatic scanning. |
SYNC/ ASYNC |
Error |
|
12065 |
No units |
Element 4 of drive's IDN table should contain the units of the IDN. The IDN has not been assigned units |
SYNC |
Error |
|
12066 |
Unit transmission too short. |
Internal error. Contact technical support. |
SYNC |
Error |
|
12067 |
Unit transmission too long |
Internal error. Contact technical support. |
SYNC |
Error |
|
12068 |
Unit cannot be changed |
Element 4 of the IDN is write-protected. Units cannot be changed |
SYNC |
Error |
|
12069 |
Unit is write protected at this time |
The units of the IDN cannot be changed in the current communication phase. |
SYNC |
Error |
|
12070 |
Incorrect value or value out of range |
Invalid value assignment at this statement. See the entry in the reference manual for this command. |
SYNC |
Error |
|
12071 |
Cannot proceed to communication phase 1: check baud rate and drive addresses |
This error occurs if the system cannot be advanced to communication phase 1. This can happen if the baud rates in the drives and controller are not matched. It can also happen if there is a conflict between the DRIVEADDRESS property and the SIMULATED property. If an axis is simulated, the drive address must be set to 0. If the axis is real, the simulated property must be set to 0 (Off). |
SYNC/ASYNC |
Error |
|
12072 |
The drive address has already been assigned to another axis |
Each axis must be assigned a unique drive address. There cannot be multiple drives with the same address. |
SYNC |
Error |
|
12073 |
Not valid for simulated axis |
Cannot perform this command for simulated axis |
SYNC |
Error |
|
12074 |
Invalid request for service channel transmission |
Internal error. Contact technical support. |
SYNC |
Fatal Fault |
Watchdog |
12075 |
Invalid data pointer |
Internal error. Contact technical support. |
SYNC |
Error |
|
12076 |
Unknown operation data type for this command |
Internal error. Contact technical support. |
SYNC |
Error |
|
12077 |
Cannot redefine default IDN |
Internal error. Contact technical support. |
SYNC |
Error |
|
12078 |
List of IDNs defined as cyclic data is too long |
The length of the IDN list declared by an user is too long. Try use simpler telegrams or contact technical support. |
SYNC |
Error |
|
12079 |
Cannot enable axis: System Enable property is off |
A drive cannot be enabled if the System.Enable property is OFF. Set this property to on to allow the drives to be enabled, and then enable the axis. |
SYNC |
Error |
|
12081 |
No minimum value |
Element 4 of drive's IDN table should contain the units of the IDN. The IDN has not been assigned a minimum value. |
SYNC |
Error |
|
12082 |
Minimum value transmission too short. |
Internal error. Contact technical support. |
SYNC |
Error |
|
12083 |
Minimum value transmission too long |
Internal error. Contact technical support. |
SYNC |
Error |
|
12084 |
Minimum value cannot be changed. |
Element 5 of the IDN is write-protected. Minimum value cannot be changed. |
SYNC |
Error |
|
12085 |
Minimum value is write protected at this time |
The minimum value of the IDN cannot be changed in the current communication phase. |
SYNC |
Error |
|
12086 |
Error of synchronization with the drive |
Synchronization between SERCOS driver and motion module lost |
ASYNC |
Note |
|
12087 |
Return back to CP0 due to a missed telegram |
Telegram missed in CP1 or CP2 |
SYNC |
Error |
|
12088 |
An error occurred on the drive |
Drive reports about Class 1 Diagnostic fault. Check IDN 95 to get the diagnostic message. |
ASYNC |
Error |
Drive is disabled |
12089 |
Drive does not respond |
This message is generated in CP1 when the master scans drive addresses. Check correspondence <axis>.DRIVEADDRESS property with the actual drive addresses. |
ASYNC |
Note |
|
12090 |
Drive telegram error |
Telegram received from the drive is not error-free. This message may be followed by the missing telegram error. |
ASYNC |
Note |
|
12091 |
The IDN being declared in cyclic data is not defined |
Check in drive IDN documentation if this IDN exists in drive. |
SYNC |
Error |
|
12092 |
Wrong operation data length for IDN |
Wrong operation data length was specified in definition of the IDN. |
SYNC |
Error |
|
12093 |
Receiving telegram over-run |
One of the SERCOS programming times was incorrect. Contact technical support. |
ASYNC |
Error |
|
12094 |
Telegram processing cannot follow receiving rate |
One of the SERCOS programming times was incorrect. Contact technical support. |
ASYNC |
Error |
|
12097 |
No maximum value. |
Element 6 of drive's IDN table should contain the units of the IDN. The IDN has not been assigned a maximum value. |
SYNC |
Error |
|
12098 |
Maximum value transmission too short. |
Internal error. Contact technical support. |
SYNC |
Error |
|
12099 |
Maximum value transmission too long |
Internal error. Contact technical support. |
SYNC |
Error |
|
12100 |
Maximum value cannot be changed. |
Element 6 of the IDN is write protected. Maximum value cannot be changed. |
SYNC |
Error |
|
12101 |
Maximum value is write protected at this time |
The maximum value of the IDN cannot be changed in the current communication phase. |
SYNC |
Error |
|
12114 |
Operation data transmission too short. |
Drive expects more information for the IDN data. Refer to the drive’s IDN manual. |
SYNC |
Error |
|
12115 |
Operation data transmission too long. |
Drive expects less information for the IDN data. Refer to the drive’s IDN manual. |
SYNC |
Error |
|
12116 |
Operation data cannot be changed |
The operation data of the IDN may not be changed. |
SYNC |
Error |
|
12117 |
Operation data is write protected at this time. |
The operation data of the IDN cannot be changed in the current communication phase. Refer to the drive’s IDN manual. |
SYNC |
Error |
|
12118 |
Operation data are smaller than the minimum value. |
Operation data of the IDN should be equal or greater than that defined in Element 5. |
SYNC |
Error |
|
12119 |
Operation data are greater than the maximum value. |
Operation data of the IDN should be equal or less than that defined in Element 6. |
SYNC |
Error |
|
12120 |
Invalid data (e.g., invalid bit combination for this IDN). |
The drive cannot accept the value written. Refer to description of the IDN entry in the Drive’s IDN manual. |
SYNC |
Error |
|
12121 |
Operation data are password write-protected |
Operation data are password write-protected. Refer to drive’s manual to get more information on IDN password protection. |
SYNC |
Error |
|
12122 |
IDN is configured in the MDT or AT, therefore writing to it over the service channel not permitted |
Operation data is write-protected at this time, since it is cyclically configured. |
SYNC |
Error |
|
12123 |
Invalid indirect addressing: (eg. data container, list handling) |
Internal error. Contact technical support. |
SYNC |
Error |
|
12124 |
Operation data is write protected at this time, due to other adjustments (e.g. parameter, operating mode, drive release, drive etc.). |
Refer to description of the IDN entry in the Drive’s IDN manual. |
SYNC |
Error |
|
12128 |
Procedure already activated |
Check IDNstate of this procedure. Refer to description of the IDN procedure entry in the Drive’s IDN manual for check limitation of this procedure |
SYNC |
Error |
|
12129 |
Procedure not interruptible |
This procedure can’t be interrupted. Refer to description of the IDN procedure entry in the Drive’s IDN manual for check limitation of this procedure |
SYNC |
Error |
|
12130 |
Procedure cannot be executed at this time (e.g. procedure in this phase cannot be activated) |
Refer to description of the IDN procedure entry in the Drive’s IDN manual for check limitation of this procedure |
SYNC |
Error |
|
12131 |
Procedure cannot be executed (invalid or false parameters) |
The parameter of this procedure is invalid. Refer to description of the IDN procedure entry in the Drive’s IDN manual. |
SYNC |
Error |
|