MC-Basic:axis.HOMETYPE

From SoftMC-Wiki
Revision as of 09:19, 22 May 2014 by Miborich (talk | contribs)
Jump to: navigation, search

This property specifies the type of homing latch:
0 – Switch and marker
1 – Switch
2 – Marker

Short form

<axis>.HTyp

Syntax

<axis>.HomeType = <value>

Availability

All versions

Type

Long

Range

0 to 2

Default

Dependent on the drive

Scope

Task or Terminal

Limitations

  • Drives without index signaling cannot use HomeType
  • Valid in communications phase 2 or higher
  • To set the value within a task, the axis must be attached to that task (using the ATTACH command)
  • Not supported in EtherCAT system

Examples

?a1.Htyp
a1.htyp = 2