Difference between revisions of "MC-Basic:axis.TORQUEERRORDISABLETYPE"
(AXY: new links) |
|||
Line 1: | Line 1: | ||
− | {{Languages}} | + | {{Languages|MC-Basic:axis.TORQUEERRORDISABLETYPE}} |
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 42: | Line 42: | ||
|SEE ALSO= | |SEE ALSO= | ||
* [[Motion Dynamics]] | * [[Motion Dynamics]] | ||
− | * [[ | + | * [[MC-Basic:element.TORQUEFEEDBACK|TORQUEFEEDBACK]] |
* [[MC-Basic:axis.TORQUEFACTOR|axis.TORQUEFACTOR]] | * [[MC-Basic:axis.TORQUEFACTOR|axis.TORQUEFACTOR]] | ||
* [[MC-Basic:axis.TORQUEADDCOMMAND|axis.TORQUEADDCOMMAND]] | * [[MC-Basic:axis.TORQUEADDCOMMAND|axis.TORQUEADDCOMMAND]] |
Latest revision as of 12:56, 13 September 2017
Language: | English • 中文(简体) |
---|
Defines the torque-error collision procedure. If the TE > TEMAX axis is disabled after it is stopped by the stop profile defined by TorqueErrorStopType, according to values of TorqueErrorDisableType:
0 normal
1 high-power
2 TBD
Short form
<axis>.TorqueErrorDisableType
Syntax
?<axis>. TorqueErrorDisableType
Availability
Since Version 4.5.x
Type
Integer
Range
0 to 2
Default
0
Scope
Configuration, Task or Terminal
Limitations
Read/Write only, Modal Only
Examples
?A1.TorqueErrroDisableType