Difference between revisions of "MC-Basic:axis.TORQUEERROR"

From SoftMC-Wiki
Jump to: navigation, search
Line 40: Line 40:
 
* [[Motion Dynamics]]
 
* [[Motion Dynamics]]
 
* [[MC-Basic:axis.TORQUEERRORDISABLETYPE|axis.TORQUEERRORDISABLETYPE]]
 
* [[MC-Basic:axis.TORQUEERRORDISABLETYPE|axis.TORQUEERRORDISABLETYPE]]
* [[MC-Basic:axis.TORQUEFEEDBACK|axis.TORQUEFEEDBACK]]
+
* [[AXY:MC-Basic:axis.TORQUEFEEDBACK|axis.TORQUEFEEDBACK]]
 
* [[MC-Basic:axis.TORQUEFACTOR|axis.TORQUEFACTOR]]
 
* [[MC-Basic:axis.TORQUEFACTOR|axis.TORQUEFACTOR]]
 
* [[MC-Basic:axis.TORQUEADDCOMMAND|axis.TORQUEADDCOMMAND]]
 
* [[MC-Basic:axis.TORQUEADDCOMMAND|axis.TORQUEADDCOMMAND]]

Revision as of 07:34, 14 August 2017

Language: [[::MC-Basic:axis.TORQUEERROR|English]]  • [[::MC-Basic:axis.TORQUEERROR/zh-hans|中文(简体)‎]]

Axis torque error value. The real-time (on-line) difference between TorqueAddCommand and TorqueFeedback.

If this value exceeds the TorqueErrorMax, the torque-error collision procedures (Stop and Disable) are activated according the user-defined setup in TorqueErrorStopType and TorqueErrorDisableType. A motion error is issued.

Short form

<axis>.TE

Syntax

?<axis>.TE

Availability

Since Version 4.5.x

Type

Double

Range

MinDouble to MaxDouble

Units

Torque

Scope

Configuration, Task or Terminal

Limitations

  • Read only
  • Modal Only

Examples

?A1.TE

See Also