Difference between revisions of "MC-Basic:axis.TORQUEERRORMAX"
Line 1: | Line 1: | ||
+ | {{Languages}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= |
Revision as of 08:26, 21 April 2017
Language: | [[::MC-Basic:axis.TORQUEERRORMAX|English]] • [[::MC-Basic:axis.TORQUEERRORMAX/zh-hans|中文(简体)]] |
---|
Axis torque error threshold value. If the TorqueError value exceeds the TorqueErrorMax, the torque-error collision procedures (Stop and Disable) are activated according the user-defined setup in TorqueErrorStopType and TorqueErrorDisableType. A motion error is issued.
Short form
<axis>.TEMAX
Syntax
?<axis>.TEMAX
Availability
Since Version 4.5.x
Type
Double
Range
0 to MAXDouble
Units
Torque
Default
100000
Scope
Configuration, Task or Terminal
Limitations
- Read/Write
- Modal only
Examples
?A1.TEMAX