This property is used to set the source is used as the position capture. This property takes the values 0 - for the motor position capture or 1 – for the external position capture .
Short form
<axis>.CapSrc
Syntax
<axis>.CaptureSource = <value>
Availability
All versions
Type
Long
Range
0 – motor
1 - external source
Default
0
Scope
Configuration, Task or Terminal
Limitations
- Can be set in SERCOS communications phase 2.
- Read only in communications phase 4
- Not supported in EtherCAT system
Examples
ser.phase=0
a1.CaptureSource = 1 ' Capture external position