This property specifies the requested velocity to be used during the home procedure.
Short form
<axis>.Hvel
Syntax
<axis>.HomeVelocity = <value>
Availability
All versions
Type
Double
Range
Limited by the drive.
Units
User velocity units
Default
Dependent on the drive
Scope
Task or Terminal
Limitations
- Value must be less than VELOCITYMAXIMUM or VMAX is used
- Valid in communications phase 2 or higher
- To set the value within a task, the axis must be attached to that task (using the ATTACH command)
- Not supported in EtherCAT system
Examples
?a1.hvel
a1.hvel = 100