Difference between revisions of "MC-Basic:axis.CountMax"
m (Text replace - "intger" to "integer") |
m |
||
Line 27: | Line 27: | ||
* [[AXY:MC-Basic:SERCMINPOS]] | * [[AXY:MC-Basic:SERCMINPOS]] | ||
− | {{Bugzilla|5339}} | + | <!-- {{Bugzilla|5339}} --> |
}} | }} |
Revision as of 09:46, 27 April 2014
There are drives as BOSCH drives where there are two standard IDN defining minimum and maximum
values of counts rollover.
This property indicates the minimum counts value of the drive.
Syntax
<axis>.CountMax = <value>
?<axis>.CountMax
Availability
From ver 4.7.14
Type
integer
Range
min-max integer
Units
counts
Default
231-1
Scope
Configuration, Task or Terminal
Limitations
- Modal
- Axis only
- Drive must be disabled