Difference between revisions of "MC-Basic:axis.CountMax"
m (Miborich moved page Axystems:MC-Basic:axis.CountMax to MC-Basic:axis.CountMax: Global renaming of Axystems: namespace into (Main):) |
|||
Line 19: | Line 19: | ||
|EXAMPLE= | |EXAMPLE= | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:axis.CountMin|axis.CountMin]] |
* [[Axystems:MC-Basic:axis.CountRollOver|axis.CountRollOver]] | * [[Axystems:MC-Basic:axis.CountRollOver|axis.CountRollOver]] | ||
* [[MC-Basic:axis.CountExtMax|axis.CountExtMax]] | * [[MC-Basic:axis.CountExtMax|axis.CountExtMax]] |
Revision as of 08:44, 22 May 2014
There are drives as BOSCH drives where there are two standard IDN defining minimum and maximum
values of counts rollover.
This property indicates the minimum counts value of the drive.
Syntax
<axis>.CountMax = <value>
?<axis>.CountMax
Availability
From ver 4.7.14
Type
integer
Range
min-max integer
Units
counts
Default
231-1
Scope
Configuration, Task or Terminal
Limitations
- Modal
- Axis only
- Drive must be disabled