{{MC-Basic
 
{{MC-Basic
|SHORT FORM= TCRateMax
+
|SHORT FORM= TCRatioMax
|SYNTAX= <axis>.TorqueChangeRateMax
+
|SYNTAX= <''axis''>.TorqueChangeRatioMax
 
|AVAILABILITY=
 
|AVAILABILITY=
|DESCRIPTION= Defines maximum speed of change from the current torque value to the given one inside torque command.
+
|DESCRIPTION= The maximum speed of change from the current torque value to the one given within the torque command.
 
|TYPE= Double
 
|TYPE= Double
 
|RANGE= 0.001 - MAxDouble
 
|RANGE= 0.001 - MAxDouble
|UNITS= Nm/sec or N/sec
+
|UNITS= Nm/s or N/s
 
|DEFAULT= 1
 
|DEFAULT= 1
 
|SCOPE= Task, Terminal
 
|SCOPE= Task, Terminal
|LIMITATIONS=Modal/Nodal .
+
|LIMITATIONS=Modal/Nodal
 
|EXAMPLE=  
 
|EXAMPLE=  
?TorqueChangeRate
+
?TorqueChangeRatioMax<br>
Torque 100 TorqueChangeRate = 1000
+
Torque 100 TorqueChangeRatio = 1000 TorqueChangeRatioMax = 1000<br>
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:TORQUE|TORQUE]]
+
* [[MC-Basic:TORQUE|TORQUE]]
* [[AXY:MC_Operational_Modes | MC Operational Modes]]
+
* [[MC-Basic:axis.TORQUECHANGERATIO| TORQUECHANGERATIO]]
* [[AXY:Operational_Modes | Operational Modes]]
+
* [[MC-Basic:axis.SUMTORQUE|SUMTORQUE ]]
}}
+
* [[OperationalModes| Operational Modes]]
[[Category:Axystems:OperationalModes]]
+
 
 +
<br><br>
 +
* ''[[AXY:MC_Operational_Modes | MC Operational Modes]]''
 +
* ''[[AXY:Operational_Modes | Operational Modes]]''}}
 +
[[Category:OperationalModes]]

Latest revision as of 07:04, 21 April 2017

Language: English  • 中文(简体)‎

The maximum speed of change from the current torque value to the one given within the torque command.

Short form

TCRatioMax

Syntax

<axis>.TorqueChangeRatioMax

Type

Double

Range

0.001 - MAxDouble

Units

Nm/s or N/s

Default

1

Scope

Task, Terminal

Limitations

Modal/Nodal

Examples

?TorqueChangeRatioMax
Torque 100 TorqueChangeRatio = 1000 TorqueChangeRatioMax = 1000

See Also