Difference between revisions of "MC-Basic:axis.CAPTURESOURCE"

From SoftMC-Wiki
Jump to: navigation, search
(Created page with '{{MC-Basic |SHORT FORM= ''<axis>.CapSrc'' |SYNTAX= ''<axis>''.CaptureSource = ''<value>'' |AVAILABILITY= All versions |DESCRIPTION= This property is used to set the source is …')
 
 
(14 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:axis.CAPTURESOURCE}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
''<axis>.CapSrc''
+
''<''axis''>.CapSrc''
  
 
|SYNTAX=
 
|SYNTAX=
''<axis>''.CaptureSource = ''<value>''
+
<''axis''>.CaptureSource = <''value''>
  
 
|AVAILABILITY=
 
|AVAILABILITY=
Line 30: Line 31:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Can be set in SERCOS communications phase 2 . Read only in communications phase 4 .
+
*Can be set in SERCOS communications phase 2.
 +
*Read only in communications phase 4  
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=
Line 38: Line 41:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:axis.CAPTURE|axis.CAPTURE]]
+
* [[MC-Basic:axis.CAPTURE|axis.CAPTURE]]
* [[Axystems:MC-Basic:axis.CAPTUREPOLARITY|axis.CAPTUREPOLARITY]]
+
* [[MC-Basic:axis.CAPTUREPOLARITY|axis.CAPTUREPOLARITY]]
* [[Axystems:MC-Basic:axis.RTCB1|axis.RTCB1]]
+
* [[MC-Basic:axis.RTCB1|axis.RTCB1]]
* [[Axystems:MC-Basic:axis.RTCB1_MODE|axis.RTCB1_MODE]]
+
* [[MC-Basic:axis.RTCB1 MODE|axis.RTCB1_MODE]]
* [[Axystems:MC-Basic:axis.RTSB1_MODE|axis.RTSB1_MODE]]
+
* [[MC-Basic:axis.RTSB1 MODE|axis.RTSB1_MODE]]
* [[Axystems:MC-Basic:IDNSTATE|IDNSTATE]]
+
* [[MC-Basic:IDNSTATE|IDNSTATE]]
 
 
  
 +
[[Category:Obsolete|axis.CAPTURESOURCE]]
 
}}
 
}}

Latest revision as of 02:02, 18 April 2017

Language: English  • 中文(简体)‎

This property is used to set the source is used as the position capture. This property takes the values 0 - for the motor position capture or 1 – for  the external position capture .

Short form

<axis>.CapSrc

Syntax

<axis>.CaptureSource = <value>

Availability

All versions

Type

Long

Range

0 – motor

1 - external source

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • Can be set in SERCOS communications phase 2.
  • Read only in communications phase 4
  • Not supported in EtherCAT system

Examples

ser.phase=0

a1.CaptureSource = 1                     ' Capture external position

See Also