Language: English  • 中文(简体)‎

The maximum speed of change from the current torque value to the one given within the torque command.

Short form

TCRatioMax

Syntax

<axis>.TorqueChangeRatioMax

Type

Double

Range

0.001 - MAxDouble

Units

Nm/s or N/s

Default

1

Scope

Task, Terminal

Limitations

Modal/Nodal

Examples

?TorqueChangeRatioMax
Torque 100 TorqueChangeRatio = 1000 TorqueChangeRatioMax = 1000