Difference between revisions of "MC-Basic:axis.HOMEOFFSET"

From SoftMC-Wiki
Jump to: navigation, search
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:axis.HOMEOFFSET}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 13: Line 14:
  
  
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
 
|TYPE=
 
|TYPE=
 
Double
 
Double
Line 30: Line 30:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
* Valid in communications phase 2 or higher.
+
*Valid in communications phase 2 or higher
* To set the value within a task, the axis must be attached to that task (using the ATTACH command).
+
*To set the value within a task, the axis must be attached to that task (using the ATTACH command)
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=
Line 39: Line 40:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:ATTACH|ATTACH]]
+
* [[MC-Basic:ATTACH|ATTACH]]
* [[Axystems:MC-Basic:HOME|HOME]]
+
* [[MC-Basic:HOME|HOME]]
  
[[Category:Axystems:Obsolete|axis.HomeOffset]]
+
[[Category:Obsolete|axis.HomeOffset]]
 
}}
 
}}

Latest revision as of 07:58, 19 April 2017

Language: English  • 中文(简体)‎

This property determines the motor position feedback relative to the machine's zero point.

Short form

<axis>.Hoff

Syntax

<axis>.HomeOffset = <value>

Availability

All versions

Type

Double

Range

Limited by the drive.

Units

User position units

Default

Dependent on the drive

Scope

Terminal and Task

Limitations

  • Valid in communications phase 2 or higher
  • To set the value within a task, the axis must be attached to that task (using the ATTACH command)
  • Not supported in EtherCAT system

Examples

?a1.hoff

a1.hoff = -50

See Also