<font color ="red">This property is used to set the digital input (on the SERVOSTAR drive) is used as the capture signal. This property takes the values 1, 2, or 3, indicating drive flex-input 1, 2, or 3. These values have keywords IN1, IN2, and IN3. The property sets the value 16 into the relevant IDN on the drive (IDN P123 for IN1; IDN P125 for IN2; IDN P127 for IN3). When the property is queried, the MC checks the drive to see if the flex-input has been set for CAPTURE.</font>
+
This property is used to set the digital input (on the drive) is used as the capture signal. This property takes the values 1, 2, or 3, indicating drive flex-input 1, 2, or 3. These values have keywords IN1, IN2, and IN3. The property sets the value 16 into the relevant IDN on the drive (IDN P123 for IN1; IDN P125 for IN2; IDN P127 for IN3). When the property is queried, the softMC checks the drive to see if the flex-input has been set for CAPTURE.</font>
  
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
  
 
{{Note|The property <''axis''>. CAPTUREINPUT is replaced in version 3.0 by the properties IN1MODE and IN1.}}
 
{{Note|The property <''axis''>. CAPTUREINPUT is replaced in version 3.0 by the properties IN1MODE and IN1.}}
Line 26: Line 26:
  
 
|DEFAULT=
 
|DEFAULT=
There is no default in the MC. When the property is queried, the MC gets the value from the drive.
+
There is no default in the softMC. When the property is queried, the softMC gets the value from the drive.
  
 
|SCOPE=
 
|SCOPE=
Line 32: Line 32:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
 
+
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=
Line 38: Line 38:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:axis.CAPTURE|axis.CAPTURE]]
+
* [[MC-Basic:axis.CAPTURE|axis.CAPTURE]]
* [[Axystems:MC-Basic:axis.CAPTUREPOLARITY|axis.CAPTUREPOLARITY]]
+
* [[MC-Basic:axis.CAPTUREPOLARITY|axis.CAPTUREPOLARITY]]
* [[Axystems:MC-Basic:axis.RTCB1|axis.RTCB1]]
+
* [[MC-Basic:axis.RTCB1|axis.RTCB1]]
* [[Axystems:MC-Basic:axis.RTCB1_MODE|axis.RTCB1_MODE]]
+
* [[MC-Basic:axis.RTCB1 MODE|axis.RTCB1_MODE]]
* [[Axystems:MC-Basic:axis.RTSB1_MODE|axis.RTSB1_MODE]]
+
* [[MC-Basic:axis.RTSB1 MODE|axis.RTSB1_MODE]]
* [[Axystems:MC-Basic:IDNSTATE|IDNSTATE]]
+
* [[MC-Basic:IDNSTATE|IDNSTATE]]
  
[[Category:Axystems:Obsolete|axis.CAPTUREINPUT]]
+
[[Category:Obsolete|axis.CAPTUREINPUT]]
  
 
}}
 
}}

Latest revision as of 01:36, 18 April 2017

Language: English  • 中文(简体)‎

This property is used to set the digital input (on the drive) is used as the capture signal. This property takes the values 1, 2, or 3, indicating drive flex-input 1, 2, or 3. These values have keywords IN1, IN2, and IN3. The property sets the value 16 into the relevant IDN on the drive (IDN P123 for IN1; IDN P125 for IN2; IDN P127 for IN3). When the property is queried, the softMC checks the drive to see if the flex-input has been set for CAPTURE.</font>


NOTE-Info.svgNOTE
The property <axis>. CAPTUREINPUT is replaced in version 3.0 by the properties IN1MODE and IN1.

Syntax

<axis>.CaptureInput = <input>

Availability

All versions

Type

Long

Range

1 to 3

Default

There is no default in the softMC. When the property is queried, the softMC gets the value from the drive.

Scope

Configuration, Task or Terminal

Limitations

  • Not supported in EtherCAT system

Examples

a1.CaptureInput = IN2  'Use IN2 for capture