MC-Basic:axis.RTCB2 MODE

From SoftMC-Wiki
Jump to: navigation, search
Language: English  • 中文(简体)‎

In SERCOS, a realtime control bit is set to activate a function by writing the IDN of that function to IDN 303. This property encapsulates that operation by enabling you to specify (<value>) only the IDN number of the function to be activated. This is useful for Capture, for example, where IDN 405 is used to arm the capture.

Syntax

<axis>.RTCB2_Mode = <value>

Availability

All versions

Type

Long

Range

Any IDN that can be activated using this mechanism.

Scope

Configuration, Task or Terminal

Limitations

  • Can only be set during SERCOS communications phase 4
  • Not supported in EtherCAT system

Examples

a1.rtcb2_mode = 405

arm capture using RTCB #2

See Also