JMobile Studio
JMobile Studio
Python script: JMobile_csv.py
Default target .csv file name: JMobile_HMI.csv (user-definable)
To import tags, perform the following procedure in JMobile Studio.
Define Protocol
1. In the ProjectView pane, select Protocols.
2. Click the blue + sign.
3. From the list, select Modbus TCP.
4. In the Modbus TCP configuration window, define:
- IP Address: Set the IP address of your softMC.
- PLC Models: Select Generic Modbus (0-based), meaning the softMC Modbus server starts addressing tags from 0.
- Click OK.
Import Tags
1. In the ProjectView pane, select Tags.
2. From the list, select Modbus TCP protocol defined previously.
3. Click the Import Tags button.
4. Open the generated file JMobile_HMI.csv.
5. Select the tags you want to add to your project, and click the Import tags button.