AXY:Basics of joint parameters identification/Verification

From SoftMC-Wiki
Jump to: navigation, search

Basics of joint parameters identification - Verification.png

The image shows a comparison between recorded torque feedback and torque computed using the identified parameters.

Repeatability of parameter identification

For testing the repeatability of implemented parameter identification algorithm the parameters of joint 2 (DR1200-4S) are identified several times consecutively. At the beginning of all measurements the joint is already in operating temperature.

Measurement
1 0,1344732 0,3389793 3,8477142 2,0104706
2 0,1345419 0,3383904 3,8244827 2,0297676
3 0,1345093 0,3334403 3,8569023 2,0208896
4 0,1345672 0,3398903 3,7731432 2,0273873
5 0,1345354 0,3346488 3,7522782 2,0209898
6 0,1345903 0,3314771 3,7464159 2,0335845
7 0,1346014 0,3246576 3,7571930 2,0183868
8 0,1346407 0,3281108 3,7361262 2,0274325
9 0,1345969 0,3239006 3,7094229 2,0246346
10 0,1346543 0,3223137 3,7282359 2,0401946
Average 0,1345711 0,3315809 3,7731915 2,0253738
Mean variation 0,13% 5,30% 3,91% 1,47%

Conclusions

As can be seen in the table all parameters can be reproducibly identified.