Activates the continuous path mode (for blending) and sets the blend radius value.
Syntax
?<element>.CP
<element>.CP = <value>
Availability
All versions
Type
Double
Range
0 to Max Double
Units
User axis position units
Default
0
Scope
Task or Terminal
Limitations
The combination of CP <> 0 and VELOCITYFINAL <> 0 is not allowed.
Mixed profiler types are not valid. Modal/Nodal.
Examples
Axis
A1.CP = 10
?A1.CP
Group
G1.CP = 10