MC-Basic:axis.HOMEACCELERATION
Revision as of 08:45, 22 May 2014 by Miborich (talk | contribs) (Miborich moved page Axystems:MC-Basic:axis.HOMEACCELERATION to MC-Basic:axis.HOMEACCELERATION: Global renaming of Axystems: namespace into (Main):)
This property specifies the requested acceleration or deceleration to be used during the HOME procedure.
Short form
<axis>.Hacc
Syntax
<axis>.HomeAcceleration = <value>
Availability
All versions
Type
Double
Range
Greater than 0 (limited by the drive)
Units
User acceleration units
Default
Dependent on the drive
Scope
Task or Terminal
Limitations
- Limited by the drive
- Valid in communications phase 2 or higher.
- To set the value within a task, the axis must be attached to that task (using the ATTACH command).
- Not supported in EtherCAT system
Examples
a1.hacc = 1000
If (a1.hacc<2000) Then
<code>
End If