AXY:Basics of joint parameters identification/Verification
The image shows a comparison between recorded torque feedback and torque computed using the identified parameters.
Repeatability of parameter identification
For testing the repeatability of implemented parameter identification algorithm the parameters of joint 2 (DR1200-4S) are identified several times consecutively. At the beginning of all measurements the joint is already in operating temperature.
Measurement | ||||
1 | 0,1344732 | 0,3389793 | 3,8477142 | 2,0104706 |
2 | 0,1345419 | 0,3383904 | 3,8244827 | 2,0297676 |
3 | 0,1345093 | 0,3334403 | 3,8569023 | 2,0208896 |
4 | 0,1345672 | 0,3398903 | 3,7731432 | 2,0273873 |
5 | 0,1345354 | 0,3346488 | 3,7522782 | 2,0209898 |
6 | 0,1345903 | 0,3314771 | 3,7464159 | 2,0335845 |
7 | 0,1346014 | 0,3246576 | 3,7571930 | 2,0183868 |
8 | 0,1346407 | 0,3281108 | 3,7361262 | 2,0274325 |
9 | 0,1345969 | 0,3239006 | 3,7094229 | 2,0246346 |
10 | 0,1346543 | 0,3223137 | 3,7282359 | 2,0401946 |
Average | 0,1345711 | 0,3315809 | 3,7731915 | 2,0253738 |
Mean variation | 0,13% | 5,30% | 3,91% | 1,47% |
Conclusions
As can be seen in the table all parameters can be reproducibly identified.