MC-Basic:HOME

From SoftMC-Wiki
Revision as of 16:00, 13 December 2010 by Arwiebe (talk | contribs) (Created page with '{{MC-Basic |SHORT FORM= |SYNTAX= Home ''<axis>'' |AVAILABILITY= All versions |DESCRIPTION= This command starts the home procedure in the drive. It implicitly sets the axis in…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

This command starts the home procedure in the drive. It implicitly sets the axis into following mode and starts the homing move. HOMEVELOCITY and HOMEACCELERATION are the values used during the home move. The type of move is determined by the HOMETYPE property. The offset and distance are determined by HOMEOFFSET and HOMEDISTANCE. In simulation mode, issuing a homing procedure flags an error. During the homing procedure, the following flag is locked to the user. When the procedure is finished, the following mode can be changed.

Syntax

Home <axis>

Availability

All versions

Scope

Task or Terminal

Limitations

Write-Only. Axis must be attached, enabled, not moving, and not a slave.

Examples

Home a1

See Also