PIPEMODE

The softMC controller can be used as a pure Motion-Bus interface card between your application and drives (PIPEMODE feature). The host computer controls all of what normally occurs in the motion module of the softMC . It must send a real-time stream of data through the softMC to the drives. In this case, the softMC functions as a data pipe. The feature is enhanced by the option of flexibly switching between pipe mode and regular mode. In typical applications, the softMC starts in regular mode where homing, jogging and initial position adjustments are made. After that, the softMC can be switched to pipe mode and the host computer takes control. There can be both softMC -controlled and pipe-controlled axes at same time in the system. Following error and velocity over-speed errors are not checked with piped axes, but by the host.

An external profiler path can be designed and fed to the softMC point-by-point. The controller functions only as a pipe and is not responsible for the correctness of the applied profiler. No system limits are checked except for position error and feedback velocity limitation. While running under this mode, no other movements are allowed.


The HostDouble data interface can be configured in one of four communication protocols using SYS.PIPEMODE:

  • 1 – sending position command only
  • 2 – sending both position and velocity commands
  • 3 - sending only velocity commands
  • 4 - sending only torque commands (TCMD)

When the system's pipe mode uses only position commands, the controller computes the current velocity.


Data Structure

The host CPU passes position , velocity and torque commands commands via a data containers. User's API maps the data to SYS.HOSTDOUBLE to external source (usually TCP/IP). The Motion-Bus operation mode of every drive connected to an axis working in Pipe Mode must be configured (Position/Velocity/Torque).


The data structure mapping depends on the PIPEMODE state:

MC variables
SYSTEM.PIPEMODE
Position (1) Position and Velocity (2)
Velocity (3)
Torq (2)
Sys.HostDouble[1]
A1.PCMD
A1.PCMD
A1.PCMD
A1.PCMD
Sys.HostDouble[2]
A2.PCMD
A1.VCMD
A2.PCMD
A2.PCMD
Sys.HostDouble[3]
A3.PCMD
A2.PCMD
A3.PCMD
A3.PCMD
Sys.HostDouble[4]
A4.PCMD
A2.VCMD
A4.PCMD
A4.PCMD
Sys.HostDouble[5]
A5.PCMD
A3.PCMD
A5.PCMD
A5.PCMD
Sys.HostDouble[6]
A6.PCMD
A3.VCMD
A6.PCMD
A6.PCMD
Sys.HostDouble[7]
A7.PCMD
A4.PCMD
A7.PCMD
A7.PCMD
Sys.HostDouble[8]
A8.PCMD
A4.VCMD
A8.PCMD
A8.PCMD
Sys.HostDouble[9]
A9.PCMD
A5.VCMD
A9.PCMD
A9.PCMD
. . . . .
Sys.HostDouble[128]
A128.PCMD
A64.VCMD
A128.PCMD
A128.PCMD