MC-Basic:pls.PLSPOLARITY
Sets or queries the initial polarity of the system output associated with a PLS. The initial polarity of a PLS is specified as 1 or 0. The output state is set when the PLS is enabled.
Short form
<pls>.Ppol
Syntax
<pls>.PlsPolarity = <polarity>
?<pls>.PlsPolarity
Availability
All versions
Type
Long
Range
0 or 1
Default
1
Scope
Configuration, Task or Terminal
Limitations
The PLS polarity is only set when the PLS is disabled.
Examples
Pls1.PlsPolarity = 0