MC-Basic:HOME
Revision as of 08:38, 22 May 2014 by Miborich (talk | contribs) (Miborich moved page Axystems:MC-Basic:HOME to MC-Basic:HOME: Global renaming of Axystems: namespace into (Main):)
This command starts the home procedure in the drive. It implicitly sets the axis into following mode and starts the homing move. HOMEVELOCITY and HOMEACCELERATION are the values used during the home move. The type of move is determined by the HOMETYPE property. The offset and distance are determined by HOMEOFFSET and HOMEDISTANCE. In simulation mode, issuing a homing procedure flags an error. During the homing procedure, the following flag is locked to the user. When the procedure is finished, the following mode can be changed.
Syntax
Home <axis>
Availability
- All versions.
- Not supported in EtherCAT system
Scope
Task or Terminal
Limitations
- Write only
- Axis must be attached, enabled, not moving, and not a slave
- Not supported in EtherCAT system
Examples
Home a1