| '''DESCRIPTION''' | | '''DESCRIPTION''' | ||
− | | this | + | | this user function mimics <axis>.countmax. |
− | | | + | | It sets a value of maximum <axis>.countFeedBack. If countFeedBack passes this value - it is reduced to SERCMINPOS, see figure. |
|- | |- |
Revision as of 07:47, 2 November 2011
Short form | N.A. | |
Syntax | ? user SET_SERCOS_MIN ( AxisNumber , value , 0 ) | |
DESCRIPTION | this user function mimics <axis>.countmax. | It sets a value of maximum <axis>.countFeedBack. If countFeedBack passes this value - it is reduced to SERCMINPOS, see figure. |
Data Type | integer (when queried) | |
Range | 04 | |
Default | 0 | |
Units | none | |
Non-Volatile | ||
Scope | Config, task, monitor | |
Write Access | Read/Write | |
Limitations | modal-only, Attachment needed | |
Examples | WoMode DTmode – setting digital mode
?WoMode – querying the current mode | |
Cross Reference |