Difference between revisions of "AXY:MC-Basic:SERCMAXPOS"
Line 1: | Line 1: | ||
{| class="prettytable" | {| class="prettytable" | ||
+ | |||
+ | <nowiki><new mode> 0</nowiki>4 | ||
+ | |||
| '''Short form''' | | '''Short form''' | ||
| '''N.A.''' | | '''N.A.''' | ||
− | |||
− | |||
|- | |- |
Revision as of 07:33, 2 November 2011
Short form | N.A. |
Syntax | ? user SET_SERCOS_MIN(,,) |
Description | Sets the operational mode explicitly:
DVmode(1) – digital velocity DTmode(2) – digital torque AVmode(3) – analog velocity mode ATmode(4) – analog torque mode* If the current mode is digital then, the mode change occurs at the end of the current movement command (Move, Jog, and DigitalTorque) when the generator completes the motion.
|
Data Type | integer (when queried) |
Range | 04 |
Default | 0 |
Units | none |
Non-Volatile | |
Scope | Config, task, monitor |
Write Access | Read/Write |
Limitations | modal-only, Attachment needed |
Examples | WoMode DTmode – setting digital mode
?WoMode – querying the current mode |
Cross Reference |