Difference between revisions of "MC-Basic:SYNCALL"

From SoftMC-Wiki
Jump to: navigation, search
(AXY: new links)
Line 1: Line 1:
{{Languages}}
+
{{Languages|MC-Basic:SYNCALL}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 37: Line 37:
 
<br/>{{Note| Movement that has '''''vFinal > 0''''' can't be used with '''''SyncAll'''''.}}
 
<br/>{{Note| Movement that has '''''vFinal > 0''''' can't be used with '''''SyncAll'''''.}}
 
<br/>{{Note| Movement that starts with SyncAll can't be blend with the previous movement. It can be blend with the next movement only if  [[MC-Basic:element.BLENDINGMETHOD|BlendingMethod ]] is from type  '''''SP''''' (supper Position).}}
 
<br/>{{Note| Movement that starts with SyncAll can't be blend with the previous movement. It can be blend with the next movement only if  [[MC-Basic:element.BLENDINGMETHOD|BlendingMethod ]] is from type  '''''SP''''' (supper Position).}}
 
+
<br/>{{Note| No comma sign "," in the list !}}
 
|EXAMPLE=
 
|EXAMPLE=
  

Revision as of 06:34, 19 June 2018

Language: English  • 中文(简体)‎

This command begins executing the specified <element>s  with pending motion commands. Motion commands pend by setting the STARTTYPE to SYNC and giving the motion command.

Similar to SyncStart command. The main difference is that both initial and final position of all elements in the given list are synchronized.

Syntax

SyncAll <element> {<element>}*

Availability

From 4.11.x

Scope

Task or Terminal

Limitations

Within a task, the specified <element> must be attached


NOTE-Info.svgNOTE
Movement that has vFinal > 0 can't be used with SyncAll.

NOTE-Info.svgNOTE
Movement that starts with SyncAll can't be blend with the previous movement. It can be blend with the next movement only if BlendingMethod is from type SP (supper Position).

NOTE-Info.svgNOTE
No comma sign "," in the list !

Examples

SyncAll SCARA PUMA DELTA