Difference between revisions of "Operating CODESYS with softMC Guide Line/zh-hans"
(Created page with "{{Languages}} = CODESYS Installation = border|800px <br/> Please download from the link received the following files: * '''‘MC_FW.ZIP’ -''' c...") |
|||
Line 1: | Line 1: | ||
{{Languages}} | {{Languages}} | ||
− | = | + | = CODESYS安装 = |
[[File:CODESYS.png|border|800px]] | [[File:CODESYS.png|border|800px]] | ||
Line 10: | Line 10: | ||
− | + | 请从链接下载以下文件: | |
− | * '''‘MC_FW.ZIP’ -''' | + | * '''‘MC_FW.ZIP’ -''' 包含softMC7 Multibus CODESYS的固件升级 |
* '''‘softMC_1_0_0_1.compiled-library’''' | * '''‘softMC_1_0_0_1.compiled-library’''' | ||
* '''‘Configurator_archive_0.4.16.7.bndl’''' | * '''‘Configurator_archive_0.4.16.7.bndl’''' | ||
Line 19: | Line 19: | ||
− | + | 请按照以下步骤进行: | |
Line 26: | Line 26: | ||
− | 1. | + | 1. 打开ControlStudio. <br/> |
− | 2. | + | 2. 连接softMC7..<br/> |
− | 3. | + | 3. 在终端输入以下命令:<br/> |
<pre> ?sys.information </pre> | <pre> ?sys.information </pre> | ||
− | : | + | :检查‘Maximum number of axes’. |
:Please send a picture of the information. | :Please send a picture of the information. | ||
3. go to: | 3. go to: |
Revision as of 10:04, 14 July 2017
语言: | [[::Operating CODESYS with softMC Guide Line|English]] • [[::Operating CODESYS with softMC Guide Line/zh-hans|中文(简体)]] |
---|
CODESYS安装
请从链接下载以下文件:
- ‘MC_FW.ZIP’ - 包含softMC7 Multibus CODESYS的固件升级
- ‘softMC_1_0_0_1.compiled-library’
- ‘Configurator_archive_0.4.16.7.bndl’
- '‘SN_UAC.LIB’
请按照以下步骤进行:
Part 1:
1. 打开ControlStudio.
2. 连接softMC7..
3. 在终端输入以下命令:
?sys.information
- 检查‘Maximum number of axes’.
- Please send a picture of the information.
3. go to:
- Tools -> Firmware Update -> choose MC_FW.ZIP
4. During the Firmware Update the MC will reboot twice.
5. After the process ends, please check the new version by typing in the terminal:
?sys.information
Now you should see (among rest):
- Version number: 0.4.16.7
- Features: CODESYS:0x61131
6. Please provide:
- Hash number
- Serial number
- Maximum number of axes (from before the upgrade – after the upgrade it should be zero until installation of the UAC).
7. Once you provide these details, you will receive UAC (User Authorization Code) and further instructions.
Part 2 (When UAC is provided):
1. Open ControlStudio.
2. Connect to softMC7.
3. Send SN_UAC.LIB to softMC by dragging it into File Manager.
4.
Loadglobal SN_UAC.LIB
5. Use the following function ‘?Set_SN_UAC_Files(byval SN_str as string, byval UAC_str as string)' :
?Set_SN_UAC_Files(“your serial number”, “your UAC”)
5. Reboot the machine.
6. Check sys.information to see maximum number of axes.
?sys.information
- When upgrade is finished, you can use the ControlStudio Configurator to create the XML file (device description file).
- Please use the Configurator training guide in the website (don’t forget to check the ‘USE CODESYS’ tab).
- In CODESYS: Please install the ‘softMC_1_0_0_1.compiled-library’ into Tools -> Library Repository (one time installation).
- In CODESYS: Please install the device description file (created by the Configurator) into Tools -> Device Repository (when using a new XML file).
Summary
Task | Reference delivered by SERVOTRONIX | Status |
---|---|---|
Firmware to support CODESYS for softMC 7 EtherCAT | MC_FW.ZIP (includes the firmware upgrade) | STX: provide FW zip file
CUSTOMER: install CODESYS Runtime and send:
STX: provide UAC number |
Install ControlStudio with Configurator | configurator_archive_0.4.16.X.bndl | Download from website |
Run Configurator | User manual: softMC_Configurator_Setup_Training_Rev.1.0.pdf | Download from website |
XML file for Device Repository | Created by ControlStudio Configurator | |
softMC.compiled-library for CODESYS | softMC_1_0_0_1.compiled-library | Download from website – version 1.0.0.1 |
CODESYS examples files for basic operation of softMC w two CDHD | FLIP_FLOP_FBD.project
FLIP_FLOP_LADDER.project FLIP_FLOP_ST.project LABELING_FBD.project LABELING_LADDER.project LABELING_ST.project MAIN_MOTION_FBD.project MAIN_MOTION_LADDER.project MAIN_MOTION_ST.project |
Download from website |
CODESYS - Procedure