Difference between revisions of "MC-Basic:axis.RTCB2"

From SoftMC-Wiki
Jump to: navigation, search
Line 40: Line 40:
 
* [[MC-Basic:axis.RTCB2 MODE|axis.RTCB2_MODE]]
 
* [[MC-Basic:axis.RTCB2 MODE|axis.RTCB2_MODE]]
  
[[Category:Axystems:Obsolete|axis.RTCB2]]
+
[[Category:Obsolete|axis.RTCB2]]
 
}}
 
}}

Revision as of 09:19, 22 May 2014

In SERCOS, a realtime control bit is set to activate a function. This property is used to set (<value>) or query realtime control bit 2. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.

Syntax

<axis>.RTCB2 = <value>

Availability

All versions

Type

Long

Range

0 or 1

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • Can only be set during SERCOS communications phase 4
  • Not supported in EtherCAT system

Examples

?x_axis.rtcb2

x_axis.rtcb2 = 1

See Also