In SERCOS, a realtime control bit is set to activate a function. This property is used to set (<value>) or query realtime control bit 2. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.
Syntax
<axis>.RTCB2 = <value>
Availability
All versions
Type
Long
Range
0 or 1
Default
0
Scope
Configuration, Task or Terminal
Limitations
- Can only be set during SERCOS communications phase 4
- Not supported in EtherCAT system
Examples
?x_axis.rtcb2