Difference between revisions of "MC-Basic:movingFrame.DOWNMASTER"

From SoftMC-Wiki
Jump to: navigation, search
 
Line 51: Line 51:
  
 
}}
 
}}
[[Category:Axystems:Motion:MovingFrame]]
+
[[Category:Motion:MovingFrame]]

Latest revision as of 09:18, 22 May 2014

The DownMaster sets points that define the upper boundary of the movingframe

tracking  as array of points. Each the array’s element is a limit definition of given degree of freedom (array index). The size of the array is the moving frame’s number of degrees of freedom. It is used to calculate the transmission rate computing the scale ratio used to calculate the current moving frame position inside the working window. The position is relative terms to the trigger position and it is in master position units.

Querying the value will return the original value given by the user and not the current used value which is offset by the trigger position.

The UpperMaster and the DownMaster, define the region for every independent axis (source). The boundaries value has to fit to the followed axis, as it is defined in MasterSource property (command / feedback / external).

Syntax

< Moving Frame >.DownMaster[ ] = <position value>

Availability

Versions 4.0.26 and higher

Type

Array of  Doubles

Range

Array size is according to NDOF

Each value according to its axis source type (position, counts or robot type).

Units

Position in Moving frame system unites

Default

0

Scope

Task or Terminal

Limitations

The number of points must be as the number of independent axes in the moving frame.The UpMaster has to be set before start tracking.

Examples

CNV.ndof = 3

CNV.MasterSource= a1.pcmd , a2.pfb, a3.pext

CNV.downmaster[1] = 10000

See Also