Difference between revisions of "MC-Basic:axis.HOMETYPE"
m |
|||
Line 10: | Line 10: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | |||
− | |||
− | |||
− | |||
− | |||
This property specifies the type of homing latch:<br> | This property specifies the type of homing latch:<br> | ||
0 – Switch and marker<br> | 0 – Switch and marker<br> | ||
Line 37: | Line 32: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | * Drives without index signaling cannot use HomeType | + | * Drives without index signaling cannot use HomeType |
− | * Valid in communications phase 2 or higher | + | * Valid in communications phase 2 or higher |
− | * To set the value within a task, the axis must be attached to that task (using the ATTACH command) | + | * To set the value within a task, the axis must be attached to that task (using the ATTACH command) |
+ | * Not supported in EtherCAT system | ||
|EXAMPLE= | |EXAMPLE= |
Revision as of 12:23, 26 March 2014
This property specifies the type of homing latch:
0 – Switch and marker
1 – Switch
2 – Marker
Short form
<axis>.HTyp
Syntax
<axis>.HomeType = <value>
Availability
All versions
Type
Long
Range
0 to 2
Default
Dependent on the drive
Scope
Task or Terminal
Limitations
- Drives without index signaling cannot use HomeType
- Valid in communications phase 2 or higher
- To set the value within a task, the axis must be attached to that task (using the ATTACH command)
- Not supported in EtherCAT system
Examples
?a1.Htyp
a1.htyp = 2