|DESCRIPTION= | |DESCRIPTION= | ||
| + | |||
| + | {{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} | ||
| + | |||
| + | |||
| + | |||
This property specifies the type of homing latch:<br> | This property specifies the type of homing latch:<br> | ||
0 – Switch and marker<br> | 0 – Switch and marker<br> | ||
| Line 15: | Line 20: | ||
2 – Marker | 2 – Marker | ||
| − | |||
| − | |||
|TYPE= | |TYPE= | ||
Revision as of 11:08, 18 March 2014
| IMPORTANT | |
| THIS PROPERTY IS OBSOLETE |
This property specifies the type of homing latch:
0 – Switch and marker
1 – Switch
2 – Marker
Short form
<axis>.HTyp
Syntax
<axis>.HomeType = <value>
Availability
All versions
Type
Long
Range
0 to 2
Default
Dependent on the drive
Scope
Task or Terminal
Limitations
- Drives without index signaling cannot use HomeType.
- Valid in communications phase 2 or higher.
- To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples
?a1.Htyp
a1.htyp = 2