Difference between revisions of "MC-Basic:WRITEIDNVALUEARRAYDOUBLE"
m (Text replace - "''<value>''" to "<''value''>") |
|||
Line 23: | Line 23: | ||
''<drive>'': Long<br> | ''<drive>'': Long<br> | ||
''<IDN number>'': Long<br> | ''<IDN number>'': Long<br> | ||
− | '' | + | <''value''>: Double Type Array name<br> |
''<size>'': Long<br> | ''<size>'': Long<br> | ||
''<IDN element>'': Long<br> | ''<IDN element>'': Long<br> |
Revision as of 08:32, 17 March 2014
This command writes the data from the preliminary declared Double Type Array to a specified element of an IDN to a specified drive. The number of elements to write is limited by <size> parameter. This function works only for IDNs containing more than one Double Type value in array method .
<element> is optional. In general, only element 7 is used (default).
IMPORTANT | |
THIS COMMAND IS OBSOLETE |
Short form
WIVALAD
Syntax
WRITEIDNVALUEARRAYDOUBLE Drive=<drive address> IDN=<IDN number> Value=<Double_type_array_name> Size=<array elements number> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}
Availability
AMCS 0.4.7.12 for SERCOS III
Type
<drive>: Long
<IDN number>: Long
<value>: Double Type Array name
<size>: Long
<IDN element>: Long
<ring>: Long
<connection>:Long
Range
<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7
<size>: 1 to maximal array element number
<ring>:1
<connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)
Default
<element>: 7
Scope
Configuration, Task or Terminal
Limitations
- Write-Only.
- Executed only in SERCOS communication phases 2, 3 and 4.
- The IDN must be defined.
- The Double Type Array must be declared preliminary.
- <size> parameter should not be more than maximal number of IDN array elements .
Examples
Example For Bosch Rexroth drive : -->common shared DoubleArr[10] as long -->WriteIdnValueArray Drive=ax1.dadd Idn=<IDN number> Value=DoubleArr size=4