This property specifies the homing latch Type
0 – Switch and marker
1 – Switch
2 – Marker
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
Short form
<axis>.HTyp
Syntax
<axis>.HomeType = <value>
Availability
All versions
Type
Long
Range
0 to 2
Default
Dependent on the drive
Scope
Task or Terminal
Limitations
Drives without index signaling cannot use HomeType. Valid in communications phase 2 or higher. To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples
?a1.Htyp
a1.htyp = 2