Revision as of 07:35, 2 November 2011
Short form | N.A. |
Syntax | ? user SET_SERCOS_MIN''(AxisNumber, value,0)'' |
Description | Sets the operational mode explicitly:
DVmode(1) – digital velocity DTmode(2) – digital torque AVmode(3) – analog velocity mode ATmode(4) – analog torque mode* If the current mode is digital then, the mode change occurs at the end of the current movement command (Move, Jog, and DigitalTorque) when the generator completes the motion.
|
Data Type | integer (when queried) |
Range | 04 |
Default | 0 |
Units | none |
Non-Volatile | |
Scope | Config, task, monitor |
Write Access | Read/Write |
Limitations | modal-only, Attachment needed |
Examples | WoMode DTmode – setting digital mode
?WoMode – querying the current mode |
Cross Reference |