Difference between revisions of "MC-Basic:element.BLENDINGPERCENTAGE"
Line 25: | Line 25: | ||
{{Note/Important| If [[MC-Basic:element.BLENDINGFACTOR|BLENDINGFACTOR]] or [[MC-Basic:element.CP|CP]] are also specified (non-default values), they will be ignored.}} | {{Note/Important| If [[MC-Basic:element.BLENDINGFACTOR|BLENDINGFACTOR]] or [[MC-Basic:element.CP|CP]] are also specified (non-default values), they will be ignored.}} | ||
− | {{Note/Important| In case of CP blending | + | {{Note/Important| In case of CP blending value of CP must be non-zero in order for BlendingPercentage to take action, however the given CP value will be ignored. }} |
|TYPE= | |TYPE= |
Latest revision as of 12:48, 21 March 2020
Language: | English |
---|
Overrides values of BLENDINGFACTOR and CP nodaly.
0% – no blending at all
100% – maximum amount of blending for the specified blending pair and specified blending method.
works for both BLENDINGMETHOD - 1(CP) and 2(SP).
IMPORTANT | |
If BLENDINGFACTOR or CP are also specified (non-default values), they will be ignored. |
IMPORTANT | |
In case of CP blending value of CP must be non-zero in order for BlendingPercentage to take action, however the given CP value will be ignored. |
Syntax
<element>. BlendingPercentage = <value>
Availability
Since Version 0.4.18.1
Type
Double
Range
0 to 100
Units
Percents
Default
0 (no blending)
Scope
Task or Terminal
Limitations
Nodal-Only property
Examples
MOVE SCARA P1 BlendingPercentage = 100