Difference between revisions of "MC-Basic:element.BLENDINGFACTOR"

From SoftMC-Wiki
Jump to: navigation, search
(new page)
 
Line 13: Line 13:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
Percentage of the movement’s length that will be not blended with the next movement.
+
 
 +
Percentage of the movement’s length that will be not blended with the next movement. Works with BLENDINGMETHOD = 2 only (SP Blending)!
  
 
0% – blending of second movement started from the beginning of the first one .
 
0% – blending of second movement started from the beginning of the first one .

Revision as of 12:24, 4 September 2018

Language: [[::MC-Basic:element.BLENDINGFACTOR|English]]  • [[::MC-Basic:element.BLENDINGFACTOR/zh-hans|中文(简体)‎]]

Percentage of the movement’s length that will be not blended with the next movement. Works with BLENDINGMETHOD = 2 only (SP Blending)!

0% – blending of second movement started from the beginning of the first one .

100% – blending of second movement started from the end of the first one (NO BLENDING) .

Syntax

?<element>.BlendingFactor

<element>. BlendingFactor  = <value>

Availability

Since Version 3.6.20

Type

Double

Range

0 to 100

Units

Percents of the segments length

Default

100 (no blending)

Scope

Task or Terminal

Limitations

Mixed profiler types are not valid , Modal/Nodal

Examples

Axis
A1.BlendingFactor = 10
?A1.BlendingFactor

Group
G1.BlendingFactor = 10
?G1.BlendingFactor

See Also