Difference between revisions of "MC-Basic:movingFrame.UPSTREAM"
m (Miborich moved page Axystems:MC-Basic:movingFrame.UPSTREAM to MC-Basic:movingFrame.UPSTREAM: Global renaming of Axystems: namespace into (Main):) |
|||
Line 55: | Line 55: | ||
}} | }} | ||
− | [[Category | + | [[Category:Motion:MovingFrame]] |
Revision as of 09:18, 22 May 2014
For every number degree of freedom the user has to delimit its region by UpStreamand DownStreamlocations.
UpStream sets points that define the lower boundary of the moving frame tracking is an array of points (in robot units) . Each the array’s element is a limit definition of a given degree of freedom (array index). The size of the array is the moving frame’s number of degrees of freedom. Upstream is the low boundary of the region. The Downstream is the upper boundary of the operation region. The upstream and downstream units are from the moving frame system units (both are from the same units).
The up/down stream limits are used for scaling position in the robot coordinate system. Those values are absolute in the robot word.
Syntax
< Moving Frame >.UpStream[ ] = <position value>
Availability
Versions 4.0.26 and higher
Type
Array of Locations
Range
Array size is according to NDOF
Units
According to the moving frame type
Scope
Task or Terminal
Limitations
The number of points must be as the number of independent axes in the moving frame. Must be set before linking.
Examples
Common shared A as location of XYZR
Common shared B as location of XYZR
Common shared C as location of XYZR
CNV.ndof = 3
CNV.UpStream[1] = A
CNV.UpStream[2] = B
CNV.UpStream[3] = C