PLS (Programmable Limit Switch) is a mechanism by which a system output is triggered when a specified position is reached. | PLS (Programmable Limit Switch) is a mechanism by which a system output is triggered when a specified position is reached. | ||
= The Problem = | = The Problem = | ||
Line 34: | Line 38: | ||
= See also = | = See also = | ||
− | *[[ | + | *[[MC-Basic:pls.PLSPropagationDelay|PLSPropagationDelay]] |
− | *[[ | + | *[[MC-Basic:pls.PLSPOLARITY|PLSPolarity]] |
− | + | *[[PLS Timing Issues| PLS Timing Issues]] | |
− | {{Bugzilla|5151}} F: asymmetric plspropagationdelay | + | |
+ | |||
+ | <!-- {{Bugzilla|5151}} F: asymmetric plspropagationdelay --> | ||
+ | |||
+ | </strike> |
Latest revision as of 09:13, 8 October 2018
Replaced by NEW PLS article - INSERT LINK
PLS (Programmable Limit Switch) is a mechanism by which a system output is triggered when a specified position is reached.
Contents
The Problem
In application the use of PLS is to control an external device. Can be a situation that there is an asymmetric behavior in enabling and disabling timing of the device. As the indication to PLS is the position without dependency on the external device there can be a case when the disabling (for example) takes longer then enable and finished later then expected. So the PLS has to be set in different timing depend on the enable/disable of the device.
Solution offered
The solution is by different timing delays that will be define for enable and disable. Those values will be taken into consider at timing calculating for setting PLS.
The PLS will be calculated according to the next folmula:
t = (PLSPropagationDelay+PLSEnableDelay)*1000 + Δt
or
t = (PLSPropagationDelay+PLSDisableDelay)*1000 + Δt
Limitation
- If the delay time is smaller the the position error delay the time can't be reached. If this option is requested a new look ahead algorithm has to be implement.
- The assumption here is that the enabling-disabling requests are followed each other, so there is no condition for two follow PLS that indicate the same setting (enable/disable).
Properties (suggestion)
PLSEnableDelay
- Type = double
- Range = 0 - MAXD
- Units = ms
- Default = 0
- Scope = Task, Terminal
- Limitation =
- Example = PLSEnableDelay = 4
PLSDisableDelay
- Type = double
- Range = 0 - MAXD
- Units = ms
- Default = 0
- Scope = Task, Terminal
- Limitation =
- Example = PLSDisableDelay = 2
See also