Difference between revisions of "MC-Basic:robot.VELOCITYSYNCROT"
(Created page with '{{MC-Basic |SHORT FORM= |SYNTAX= ''<ROBOT>.''VelocitySyncRot = <''numeric expression''> |AVAILABILITY= Version 0.4.0.22 and higher |DESCRIPTION= Limits robot velocity of the …') |
|||
(9 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:robot.VELOCITYSYNCROT}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 7: | Line 8: | ||
|AVAILABILITY= | |AVAILABILITY= | ||
− | Version | + | Since Version 4.0.22 |
|DESCRIPTION= | |DESCRIPTION= | ||
Line 28: | Line 29: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | + | Read/Write, Modal Only | |
|EXAMPLE= | |EXAMPLE= | ||
Line 34: | Line 35: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:robot.VELOCITYDESYNCROT|robot.VELOCITYDESYNCROT]] |
− | * [[ | + | * [[MC-Basic:robot.VELOCITYDESYNCTRAN|robot.VELOCITYDESYNCTRAN]] |
− | * [[ | + | * [[MC-Basic:robot.VELOCITYSYNCTRAN|robot.VELOCITYSYNCTRAN]] |
}} | }} | ||
+ | [[Category:Motion:MovingFrame]] |
Latest revision as of 03:31, 27 April 2017
Language: | English • 中文(简体) |
---|
Limits robot velocity of the rotational moving frame componenet during synchronization process (from the time tracking is started (e.g. Slave=5) until it is synchronized with moving frame <robot>.IMFS = 1)
Syntax
<ROBOT>.VelocitySyncRot = <numeric expression>
Availability
Since Version 4.0.22
Type
Double
Range
0 to MaxDouble
Units
deg/sec
Default
4000
Scope
Configuration, Task or Terminal
Limitations
Read/Write, Modal Only
Examples
Scara.VelocitySyncRot = 500