Latest revision as of 13:34, 13 September 2017
Language: | English • 中文(简体) |
---|
The BF of the previous motion meant to be applied between the previous motion and the current one. If no such overwriting is desired BFPrev must be set to -1.
Percentage of the movement length that will be not blended with the next movement.
0% – blending of second movement started from the beginning of the first one.
100% – blending of second movement started from the end of the first one (no blending).
Short form
BFPrev
Syntax
?<element>.BlendingFactorPrevious
<element>.BlendingFactorPrevious = <value>
Type
Double
Range
-1 to 100
Units
Percents of the segments length
Default
-1 (not active)
Scope
Task or Terminal
Limitations
Mixed profiler types are not valid , Modal/Nodal
Examples
Axis
A1.BlendingFactorPrevious= 10
?A1.BlendingFactorPrevious
Group
G1.BlendingFactorPrevious= 10
?G1.BlendingFactorPrevious