In SERCOS, a realtime control bit is set to activate a function. This property is used to set (<value>) or query realtime control bit 2. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.

Syntax

<axis>.RTCB2 = <value>

Availability

All versions

Type

Long

Range

0 or 1

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • Can only be set during SERCOS communications phase 4
  • Not supported in EtherCAT system

Examples

?x_axis.rtcb2

x_axis.rtcb2 = 1