Difference between revisions of "MC-Basic:axis.HOMEPOLARITY"
(2 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.HOMEPOLARITY}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 42: | Line 43: | ||
* [[MC-Basic:HOME|HOME]] | * [[MC-Basic:HOME|HOME]] | ||
− | [[Category | + | [[Category:Obsolete|axis.HomePolarity]] |
}} | }} |
Latest revision as of 08:04, 19 April 2017
Language: | English • 中文(简体) |
---|
This property specifies the homing switch edge.
1 – rising edge
2 – falling edge
Short form
<axis>.Hpol
Syntax
<axis>.HomePolarity = <value>
Availability
All versions
Type
Long
Range
1 or 2
Default
Dependent on the drive
Scope
Task or Terminal
Limitations
- Valid in communications phase 2 or higher
- To set the value within a task, the axis must be attached to that task (using the ATTACH command)
- Not supported in EtherCAT system
Examples
a1.hpol = 1