Difference between revisions of "MC-Basic:WRITEIDNVALUEDOUBLE"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<connection>''" to "<''connection''>")
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:WRITEIDNVALUEDOUBLE}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 17: Line 18:
 
<''element''> is optional. In general, only element 7 is used (default).  
 
<''element''> is optional. In general, only element 7 is used (default).  
  
{{Note/Important| '''THIS COMMAND IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=
''<drive>'': Long<br>
+
<''drive''>: Long<br>
''<IDN number>'': Long<br>
+
<''IDN number''>: Long<br>
 
<''value''>: Double<br>
 
<''value''>: Double<br>
''<IDN element>'': Long
+
''<IDN element''>: Long
 
<''ring''>: Long
 
<''ring''>: Long
 
<''connection''>:Long
 
<''connection''>:Long
Line 29: Line 29:
  
 
|RANGE=
 
|RANGE=
''<drive>'': 1 to 254<br>
+
<''drive''>: 1 to 254<br>
''<IDN number>'': 1 to 65535<br>
+
<''IDN number''>: 1 to 65535<br>
''<IDN element>'': 1 to 7
+
<''IDN element''>: 1 to 7
 
<''ring''>:1
 
<''ring''>:1
 
<''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)
 
<''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)
Line 47: Line 47:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
* Write only.  
+
*Write only.  
* Executed only in SERCOS communication phases 2, 3 and 4.  
+
*Executed only in SERCOS communication phases 2, 3 and 4.
* The IDN must be defined.
+
*The IDN must be defined
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=
Line 64: Line 65:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:IDNSTRING|IDNSTRING]]
+
* [[MC-Basic:IDNSTRING|IDNSTRING]]
* [[Axystems:MC-Basic:IDNVALUE|IDNVALUE]]
+
* [[MC-Basic:IDNVALUE|IDNVALUE]]
* [[Axystems:MC-Basic:WRITEIDNSTRING|WRITEIDNSTRING]]
+
* [[MC-Basic:WRITEIDNSTRING|WRITEIDNSTRING]]
  
[[Category:Axystems:Obsolete|WRITEIDNVALUEDOUBLE]]
+
[[Category:Obsolete|WRITEIDNVALUEDOUBLE]]
  
 
}}
 
}}

Latest revision as of 17:11, 2 May 2017

Language: English  • 中文(简体)‎

This command writes the Double Type Value of a specified element of an IDN to a specified drive. It is used when writing to an IDN that takes Double Type numeric values.

<element> is optional. In general, only element 7 is used (default).

Short form

WIVALD

Syntax

WRITEIDNVALUEDOUBLE Drive=<drive address> IDN=<IDN number> Value=<value {,<value>}> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}

Availability

Since Version 4.7.12 for SERCOS III

Type

<drive>: Long
<IDN number>: Long
<value>: Double
<IDN element>: Long <ring>: Long <connection>:Long

Range

<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7 <ring>:1 <connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)

Units

<Value> : Double

Default

<element>: 7

Scope

Configuration, Task or Terminal

Limitations

  • Write only.
  • Executed only in SERCOS communication phases 2, 3 and 4.
  • The IDN must be defined
  • Not supported in EtherCAT system

Examples

WriteIdnValueDouble Drive=2 Idn=<IDN number> Value=10000       
 

for SERCOS III :

WriteIdnValue Drive=2 Idn=<IDN number> Value=10000 Element= 7 Ring= 1 Connection= 0


See Also