|DESCRIPTION=
 
This flag indicates whether a table is monotonic. Only the monotonicity of the master data is relevant.  
 
This flag indicates whether a table is monotonic. Only the monotonicity of the master data is relevant.  
 
  
 
The monotonicity of a table is checked when:
 
The monotonicity of a table is checked when:
Line 18: Line 18:
 
*Camming is engaged by setting the Slave property to the value 2.
 
*Camming is engaged by setting the Slave property to the value 2.
  
The Cam tables must be monotonic in order to be used.
+
The cam tables must be monotonic in order to be used.
  
 
|TYPE=
 
|TYPE=
Line 42: Line 42:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:CHECKCAMMONOTONIC|CHECKCAMMONOTONIC]]
+
* [[MC-Basic:CHECKCAMMONOTONIC|CHECKCAMMONOTONIC]]
* [[Axystems:MC-Basic:CREATECAMDATA|CREATECAMDATA]]
+
* [[MC-Basic:CREATECAMDATA|CREATECAMDATA]]
* [[Axystems:MC-Basic:LOADCAMDATA|LOADCAMDATA]]
+
* [[MC-Basic:LOADCAMDATA|LOADCAMDATA]]
  
  
 
}}
 
}}

Latest revision as of 08:20, 25 April 2017

Language: English  • 中文(简体)‎

This flag indicates whether a table is monotonic. Only the monotonicity of the master data is relevant.

The monotonicity of a table is checked when:

  • Data is loaded using the LOADCAMDATA command
  • The function CHECKCAMMONOTONIC() is executed
  • Camming is engaged by setting the Slave property to the value 2.

The cam tables must be monotonic in order to be used.

Short form

Imon

Syntax

?<cam>.IsMonotonic

Availability

All versions

Type

Long

Range

0 or 1

Scope

Configuration, Task or Terminal

Examples

?Cam1.Imon