Difference between revisions of "MC-Basic:axis.SLAVEDEVIATION"
m |
|||
(9 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.SLAVEDEVIATION}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 7: | Line 8: | ||
|AVAILABILITY= | |AVAILABILITY= | ||
− | Version | + | Since Version 4.0.27 |
|DESCRIPTION= | |DESCRIPTION= | ||
Variable used for monitoring differences between actual master and slave positions. | Variable used for monitoring differences between actual master and slave positions. | ||
− | For gearing | + | For gearing: |
+ | :SlaveDeviation = <''slave''>.pfb – GearRatio × <''master''>.pfb | ||
− | For camming | + | For camming: |
+ | :SlaveDeviation = <''slave''>.pfb – CAM(<''master''>.pfb) | ||
When the mastersource is <''master''>.pfb there will be no difference between <''slave''>.pemax and <''slave''>.slavedeviation. | When the mastersource is <''master''>.pfb there will be no difference between <''slave''>.pemax and <''slave''>.slavedeviation. | ||
The value is automatically monitored and checked against | The value is automatically monitored and checked against | ||
− | <''slave''>.SlaveMaxDeviation. If | + | <''slave''>.SlaveMaxDeviation. If the allowed deviation value is exceeded, an error will be returned. |
|TYPE= | |TYPE= | ||
Line 44: | Line 47: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:axis.SLAVEDISABLE|axis.SLAVEDISABLE]] |
− | * [[ | + | * [[MC-Basic:axis.SLAVEMAXDEVIATION|axis.SLAVEMAXDEVIATION]] |
− | * [[ | + | * [[MC-Basic:axis.MASTERSOURCE|axis.MASTERSOURCE]] |
− | * [[ | + | * [[MC-Basic:axis.MASTERSYNC|axis.MASTERSYNC]] |
− | * [[ | + | * [[MC-Basic:axis.SLAVELAG|axis.SLAVELAG]] |
}} | }} |
Latest revision as of 02:11, 21 April 2017
Language: | English • 中文(简体) |
---|
Variable used for monitoring differences between actual master and slave positions.
For gearing:
- SlaveDeviation = <slave>.pfb – GearRatio × <master>.pfb
For camming:
- SlaveDeviation = <slave>.pfb – CAM(<master>.pfb)
When the mastersource is <master>.pfb there will be no difference between <slave>.pemax and <slave>.slavedeviation.
The value is automatically monitored and checked against <slave>.SlaveMaxDeviation. If the allowed deviation value is exceeded, an error will be returned.
Syntax
?<Axis>.SlaveDeviation
Availability
Since Version 4.0.27
Type
Double
Range
0 to MaxDouble
Units
Position units
Scope
Configuration, Task or Terminal
Limitations
- Read only
- Modal only
Examples
Axis1.SlaveDeviation