Difference between revisions of "MC-Basic:axis.HALTRESTART"

From SoftMC-Wiki
Jump to: navigation, search
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:axis.HALTRESTART}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 4: Line 5:
  
 
|SYNTAX=
 
|SYNTAX=
''<axis>.''HaltRestart = ''<expression>''<br>
+
<''axis''>.HaltRestart = <''expression''><br>
  
?''<axis>''.HaltRestart
+
?<''axis''>.HaltRestart
  
 
|AVAILABILITY=
 
|AVAILABILITY=
Line 12: Line 13:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
This property allows direct control over control bit 13. Control bit 13 is used to control the HALTRESTART function of the drive. The bit must be cleared in order for drive faults to be cleared (using IDN 99). The MC automatically clears this bit when a drive C1D fault occurs and automatically sets it when the fault has been cleared.
+
This property allows direct control over control bit 13. Control bit 13 is used to control the HALTRESTART function of the drive. The bit must be cleared in order for drive faults to be cleared (using IDN 99). The softMC automatically clears this bit when a drive C1D fault occurs and automatically sets it when the fault has been cleared.
 
 
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=
Line 32: Line 31:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Executed only in SERCOS communication phase 4.
+
*Executed only in SERCOS communication phase 4
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=
Line 40: Line 40:
  
  
[[Category:Axystems:Obsolete|axis.HALTRESTART]]
+
[[Category:Obsolete|axis.HALTRESTART]]
  
 
}}
 
}}

Latest revision as of 06:52, 19 April 2017

Language: English  • 中文(简体)‎

This property allows direct control over control bit 13. Control bit 13 is used to control the HALTRESTART function of the drive. The bit must be cleared in order for drive faults to be cleared (using IDN 99). The softMC automatically clears this bit when a drive C1D fault occurs and automatically sets it when the fault has been cleared.

Syntax

<axis>.HaltRestart = <expression>

?<axis>.HaltRestart

Availability

All versions

Type

Long

Range

0 or 1

Scope

Configuration, Task or Terminal

Limitations

  • Executed only in SERCOS communication phase 4
  • Not supported in EtherCAT system

Examples

A1.HaltRestart = 1