Difference between revisions of "MC-Basic:WRITEIDNVALUEARRAYDOUBLE"

From SoftMC-Wiki
Jump to: navigation, search
(Created page with "{{MC-Basic |SHORT FORM= WIVALAD |SYNTAX= WRITEIDNVALUEARRAYDOUBLE Drive=<drive address> IDN=<IDN number> Value=<Double_type_array_name> Size=<array elements number> {Element=...")
 
 
(15 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:WRITEIDNVALUEARRAYDOUBLE}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 5: Line 6:
 
|SYNTAX=
 
|SYNTAX=
 
WRITEIDNVALUEARRAYDOUBLE Drive=<drive address> IDN=<IDN number> Value=<Double_type_array_name> Size=<array elements number> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}
 
WRITEIDNVALUEARRAYDOUBLE Drive=<drive address> IDN=<IDN number> Value=<Double_type_array_name> Size=<array elements number> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}
 
  
 
|AVAILABILITY=
 
|AVAILABILITY=
AMCS 0.4.7.12 for SERCOS III
+
Since Version 4.7.12 for SERCOS III
  
 
|DESCRIPTION=
 
|DESCRIPTION=
Line 16: Line 16:
  
  
''<element>'' is optional. In general, only element 7 is used (default).  
+
<''element''> is optional. In general, only element 7 is used (default).  
 +
 
  
 
|TYPE=
 
|TYPE=
''<drive>'': Long<br>
+
<''drive''>: Long<br>
''<IDN number>'': Long<br>
+
<''IDN number>: Long<br>
''<value>'': Double Type Array name<br>
+
<''value''>: Double Type Array name<br>
''<size>'': Long<br>
+
<''size''>: Long<br>
''<IDN element>'': Long<br>
+
<''IDN element''>: Long<br>
''<ring>'': Long<br>
+
<''ring''>: Long<br>
''<connection>'':Long<br>
+
<''connection''>:Long<br>
  
  
 
|RANGE=
 
|RANGE=
''<drive>'': 1 to 254<br>
+
<''drive''>: 1 to 254<br>
''<IDN number>'': 1 to 65535<br>
+
<''IDN number''>: 1 to 65535<br>
''<IDN element>'': 1 to 7<br>
+
<''IDN element''>: 1 to 7<br>
''<size>'': 1 to maximal array element number <br>
+
<''size''>: 1 to maximal array element number <br>
''<ring>'':1<br>
+
<''ring''>:1<br>
''<connection>'':0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)<br>
+
<''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)<br>
  
  
Line 41: Line 42:
  
 
|DEFAULT=
 
|DEFAULT=
''<element>'': 7
+
<''element''>: 7
  
 
|SCOPE=
 
|SCOPE=
Line 47: Line 48:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
* Write-Only.
+
*Write only
* Executed only in SERCOS communication phases 2, 3 and 4.  
+
*Executed only in SERCOS communication phases 2, 3 and 4.  
* The IDN must be defined.
+
*The IDN must be defined.
* The Double Type Array must be declared preliminary.
+
*The Double Type Array must be declared preliminary.
* <size> parameter should not be more than maximal number of IDN array elements .
+
*<size> parameter should not be more than maximal number of IDN array elements .
 
+
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=
 
<pre>
 
<pre>
 
+
Example For Bosch Rexroth drive:
Example For Bosch Rexroth drive :
 
 
 
 
-->common shared DoubleArr[10] as long  
 
-->common shared DoubleArr[10] as long  
 
 
 
-->WriteIdnValueArray Drive=ax1.dadd Idn=<IDN number> Value=DoubleArr size=4  
 
-->WriteIdnValueArray Drive=ax1.dadd Idn=<IDN number> Value=DoubleArr size=4  
 
 
 
 
</pre>
 
</pre>
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:IDNSTRING|IDNSTRING]]
+
* [[MC-Basic:IDNSTRING|IDNSTRING]]
* [[Axystems:MC-Basic:IDNVALUE|IDNVALUE]]
+
* [[MC-Basic:IDNVALUE|IDNVALUE]]
* [[Axystems:MC-Basic:WRITEIDNSTRING|WRITEIDNSTRING]]
+
* [[MC-Basic:WRITEIDNSTRING|WRITEIDNSTRING]]
  
 +
[[Category:Obsolete|WRITEIDNVALUEARRAYDOUBLE]]
  
 
}}
 
}}

Latest revision as of 17:09, 2 May 2017

Language: English  • 中文(简体)‎

This command writes the data from the preliminary declared Double Type Array to a specified element of an IDN to a specified drive. The number of elements to write is limited by <size> parameter. This function works only for IDNs containing more than one Double Type value in array method .


<element> is optional. In general, only element 7 is used (default).

Short form

WIVALAD

Syntax

WRITEIDNVALUEARRAYDOUBLE Drive=<drive address> IDN=<IDN number> Value=<Double_type_array_name> Size=<array elements number> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}

Availability

Since Version 4.7.12 for SERCOS III

Type

<drive>: Long
<IDN number>: Long
<value>: Double Type Array name
<size>: Long
<IDN element>: Long
<ring>: Long
<connection>:Long

Range

<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7
<size>: 1 to maximal array element number
<ring>:1
<connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)

Default

<element>: 7

Scope

Configuration, Task or Terminal

Limitations

  • Write only
  • Executed only in SERCOS communication phases 2, 3 and 4.
  • The IDN must be defined.
  • The Double Type Array must be declared preliminary.
  • <size> parameter should not be more than maximal number of IDN array elements .
  • Not supported in EtherCAT system

Examples

Example For Bosch Rexroth drive:
-->common shared DoubleArr[10] as long 
-->WriteIdnValueArray Drive=ax1.dadd Idn=<IDN number> Value=DoubleArr size=4 

See Also