Difference between revisions of "MC-Basic:SYSTEM.ANIN.sim"
(Created page with "{{Languages|MC-Basic:SYSTEM.ANIN.sim}} {{MC-Basic |SHORT FORM= Sys.AnIn[Index].sim<br> |SYNTAX= ?System.AnIn[Index]sim<br> |AVAILABILITY= Version 0.4.20.5r8-C2 or higher |...") |
(No difference)
|
Revision as of 06:47, 30 March 2022
Language: | English |
---|
Exactly the same as Sys.ANOUT[Index].sim
Used to set an analog Input as simulated.
Once an output was set as simulated, there is no meaning to all other analog properties.
The analog output becomes a simple double variable that holds a certain value regardless of its real arrangement in the digital infrastructure.
Any index can be set as simulated in the analog array.
Short form
Sys.AnIn[Index].sim
Syntax
?System.AnIn[Index]sim
Availability
Version 0.4.20.5r8-C2 or higher
Type
long
Range
1 or 0
Default
0
Scope
Configuration, Task or Terminal
Limitations
Read or write.
Examples
- -->Sys.AnIn[1].sim = 1